Procedure 6.2 - Troubleshooting The Keypad And Upper Pca - Precor EFX5.31 Instruction Manual

Elliptical fitness crosstrainer
Hide thumbs Also See for EFX5.31:
Table of Contents

Advertisement

Procedure 6.2 - Troubleshooting the Keypad and Upper PCA

If the function keys on the electronic console are unresponsive, the problem may be either the
upper PCA or keypad.
Procedure
1.
Set the on/off switch in the "off" position.
WARNING
Before continuing with this procedure, review the Warning and Caution statements listed in
Section One.
2.
If the EFX powers up and functions normally until a particular key(s) is pressed, skip to step
10. If a "STUCK KEY" message is immediately displayed when the EFX is powered up,
continue with the next step.
3.
This condition may be caused by either one of the keypads or upper PCA. Set the on/off
switch in the "off" position. Remove the display bracket cover from the rear of the display.
Disconnect heart rate cables. Disconnect the data cable from the Upper PCA. See Diagram
6.2.
4.
Remove the three screws that fasten the accessory tray to the upper portion of the display.
Remove the four screws that fasten the display housing front panel to the display housing
back panel.
5.
Lift the display housing front panel off of the display housing backing plate. Remove the
keypad cable and the D Pad cable from the upper PCA. See Diagram 6.3.
Diagram 6.3 - Upper PCA & Keypad
HR Input Cable
Data Cable
Connector
Keypad Cable
D Pad Cable
Metrics PCA
D Pad PCA
Upper PCA
Metrics Cable
HR Output Cable
HR Output
Connector
HR PCA