Actuator Switch Back / Switch Back Sensor - Konica Minolta bizhub 20 Service Manual

Hide thumbs Also See for bizhub 20:
Table of Contents

Advertisement

9.8.33 Actuator Switch Back / Switch Back Sensor

(1) Push down the Stopper, slide the Actuator switch back to the stopper side and pull up
the Actuator switch back to remove.
Lower main chute
(2) Release the Hooks of the Switch back sensor to remove the Switch back sensor from
the Lower main chute.
(3) Disconnect the Connector from the Switch back sensor.
Lower main chute
Actuator switch back
Fig. 5-87
Connector
Hook
Hook
Fig. 5-88
5-79
Stopper
Switch back sensor
Hook
Confidential