<WSW24> (TAD setting 2)
Selector No.
1
Maximum OGM recording time
(Not used.)
2
Time length from CML ON to
3
start of pseudo ring backtone
4
transmission
5
Attenuator for playback of ICM/
I
OGM to the line
(Not used.)
8
• Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone
transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring
backtone transmission.
In models with OGM facilities, the settings made by these selectors also apply to the length
of time from CML-ON up to the start of OGM transmission.
<WSW25> (TAD setting 3)
Selector No.
1
Not used.
2
3
External TAD no-tone detection
level
4
5
Pause between paging number
I
and PIN (Not used.)
7
8
Not used.
Note:
• Selectors 5 through 7 are applicable to the U.S.A. model only.
• Selectors 3 and 4: External TAD no-tone detection level
These selectors set the no-tone detection level in the external TAD mode.
Function
No. 3 4
Function
No. 3 4
App. 1-28
Setting and Specifications
0 0: 4 sec.
0 1: 3 sec.
1 0: 2 sec.
1 1: 1 sec.
Setting and Specifications
0 0: -43 dB (A)
0 1: -46 dB (B)
1 0: -49 dB (C)
1 1: -51 dB (D)