(5) Remove the three bind B M4x12 Taptite screws and cup S M3x6 Taptite screw, and then
remove the Main shield plate ASSY.
Taptite, bind B M4x12
Taptite, bind B M4x12
Taptite, cup S M3x6
Main shield plate ASSY
Frame L
Fig. 5-137
Assembling Note:
• Hang the Tip of the Switch arm spring of the Main shield plate on the Eject gear 28
sector.
Eject gear 28 sector
Main Shield Plate ASSY
Switch arm spring
Fig. 5-138