13 Configure the alarm settings [Alarm]
[Notification data]
Enter the notification data to add after the destination HTTP server addresses set in [Address 1] - [Address
5].
Available characters: Alphanumeric characters
Default: /cgi-bin/comalarm.cgi?CMD=01
Note
For "Address 1" to "Address 5", a total of 256 characters can be entered for the address (including
"http://") and "Notification data".
Make sure to enter a slash (/) as the first character for "Notification data".
If the HTTP alarm notification fails, information about the failure will be added to the system log.
Even if the [Set] button is clicked after deleting the contents of "Notification data", "/cgi-bin/
comalarm.cgi?CMD=01" will be set.
HTTPS cannot be used.
<Example>
When http://192.168.0.100 is set for the address and /cgi-bin/comalarm.cgi?CMD=01 is set for "Notification
data", an HTTP alarm notification such as http://192.168.0.100/cgi-bin/comalarm.cgi?CMD=01 will be
executed.