4-9. Setting And Using Weld Parameters From Memory

P1

4-10. Setup Push Button And Advanced Programming

P2
Press P2 to enter SET UP menu.
SET UP will appear on D1 and D2 only mo-
mentarily and then change to the selected
process parameter values.
Setup allows viewing and changing default
parameter values for all welding processes
for the desired weld characteristics.
D1 shows the welding parameter.
D2 shows the parameter value.
E1 changes the welding parameter.
OM-221 694 Page 20
E2 changes the parameter value.
.
Incorrect settings in any process can
result in a program with undesirable
weld characteristics. Setup should
only be used by operators familiar with
various welding processes and pa-
rameters.
Pressing P2 again allows changing wire
type selections (see Section 4-4).
.
Check memory parameter for
proper settings before the
selections.
Four memory selections are avail-
able for each welding process (20
total).
These memory selections provide
quick changes to welding pro-
cesses with preset parameter val-
ues. All memory selections have
factory set defaults and may re-
quire changes for the desired weld
characteristics.
Press P1 until desired memory
selection LED illuminates.
Setting Menu Type
.
MENU EASY only shows basic pa-
rameters for welding processes.
MENU FULL shows all parameters for
welding processes.
To set menu type, proceed as follows:
Press P2 to enter SET UP menu.
Use E1 to select MENU EASY on D1 and
D2 (default setting).
Use E2 to change D2 to FULL.