3-7. Remote Receptacle Information
.
This unit automatically uses the remote control if connected to the remote receptacle.
A
B
C
D
E
* The remaining sockets are not used.
Notes
Socket*
REMOTE
A
Contact closure to B completes 24 volts ac con-
tactor control circuit.
B
Contact closure to A completes 24 volts ac con-
tactor control circuit.
REMOTE
C
Output to remote control; +10 volts dc.
CONTROL
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from re-
mote control.
Socket Information