Rep 2.0.11 Drum Maintenance Camshaft - Xerox Phaser 8560MFP Service Documentation

Hide thumbs Also See for Phaser 8560MFP:
Table of Contents

Advertisement

Figure 2 Removing the Transfix Camshaft
Initial Issue
Phaser 8510/8560MFP Multifunction Product

REP 2.0.11 Drum Maintenance Camshaft

Parts List on PL 2.0
Removal
1.
Remove the Drum Maintenance Pivot Plate (REP 2.0.16).
2.
Remove the Process Drive (REP 4.0.7).
3.
Slide the camshaft to the right, release the bushing by carefully prying it from the ground
plate, Move the left end of the camshaft towards the rear of the printer move the camshaft
to the right, then lift the camshaft through the slot while removing it to the right.
Figure 1 Removing the Drum Maintenance Camshaft
Replacement
Replace the KL-Clips on the outside grooves of the Drum Maintenance Camshaft, and perform
the Head Tilt Gear (ADJ 4.13.1), and Process Drive Alignment (ADJ 4.7.1) adjustments before
restoring system power.
10/2006
4-29
Repairs and Adjustments
REP 2.0.10, REP 2.0.11