Running A Program To Preheat Or Stress Relief - Miller Electric IH Owner's Manual

Single induction heating power source temperature control/recorder
Table of Contents

Advertisement

6-3-4.

Running A Program To Preheat Or Stress Relief

To start the Heat Treat operation, proceed as follows:
Press the "RUN" button − The blue "Heat On" light turns on and the power source energizes.
To adjust profile during the Heat Treat operation, proceed as follows:
Press the "HOLD" button − The controller displays "HOLD", but the heat is maintained at the present target
When cycle completes or to abort the process, fully press the "STOP" button − controller resets to segment 1 and
power source contactor relays open.
OM-203 185 Page 30
The power source parameters are displayed on the "Parameter Display".
The controller flashes "Hold" until the measured temperature climbs to within the
"Hold Back" window (10 ) of the target temperature.
temperature.
Press
"Page" button until "ProG LiSt" appears on the display.
Press
"Scroll" button to select the desired parameter for changing.
Use
or
"Up" or "Down" button to change value.
Y
B
Press
"Page" button until parameter screen appears on the display.
Press "RUN" button to resume program.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts

Table of Contents