6-3. Operation

1. Energize IH/TS and power source. A coolant flow error should appear on the IH/TS display. Energize the
cooler and the error will clear from the display.
2. Set up Temperature Profile − per code requirements (see Section 6-3-2 Programming The 2408 Controller).
3. Set up and start Digital Recorder
Digital Recorder (see Section 6-3-3. Batch Recording On The 5100 Digital Recorder)
4. Run the heat process (see Section 6-3-4. Running A Heat Treat and the following tables).
5. Recover from an interruption, if applicable (see Section 6-3-5. Recovering From An Interruption).
6. Retrieve data
Digital Recorder (see Section 6-3-3-4. Batch Recording On The 5100 Digital Recorder)
View and print data (see Section 6-3-6 Review Software).
Name
Home
OP
run
StAt
PSP
SEG
StyP
SEG.t
tGt
rAtE
PrG.t
SEG.d
FASt
*This parameter can only be changed when the program is in reset.
Table 6-1. Controller Display Definitions
Description
Home List (extra parameters may be present.)
Measured value and Setpoint
% Output level
Table 6-2. Run List Sub-Menu Definitions
program run List
OFF
run
hoLd
Program status (
,
,
Programmer setpoint
Active segment number
Active segment type
Segment time remaining in the segment units
Target setpoint
Ramp rate (if a rate segment)
Program time remaining in hours
*Flash active segment type in the lower readout of the home display (no/YES)
Runs through program 10 times faster than normal
HbAc
End
,
,
)
OM-203 185 Page 19