Troubleshooting - Windsor 10020430 Operating Instructions Manual

Lightning bdp 50/2000 w
Table of Contents

Advertisement

Troubleshooting

Problem
Breaker tripped
Incorrect battery connection
Machine will not
turn on.
On-board battery charger plugged in
Key switch failure
Failed fuse
Deck tilted into pad change position
Speed control knob turned all the way
counterclockwise (off)
Burnish motor will
not turn on
Burnish switch off
Handle levers not engaged
Battery lockout
Red LED flashing
Check alarm code reference sheet
on Dash
Pad dirty
Machine exhibits
poor burnishing
Incorrect pad
performance
Pad worn down
Machine exhibits
Gas spring faulty
very aggressive
burnish
Incorrect pad
performance
Dust collection is bad, is not collecting
dust
Dust collection not
working properly
Skirt is not sealing to the floor
Possible Cause
86408910 Lightning BDP 50-2000 W
Remedy
Push breaker button to reset.
Check batteries are wired together correctly via
the battery connection diagram, check that the
Anderson connectors are plugged together.
Unplug the charging cord from the machine.
Check key switch is functioning and wiring to the
key switch is correct.
Check the fuse in the in line fuse holder.
Lower the deck to the burnish position.
Turn speed control knob clockwise to increase
speed
Turn burnish switch on.
Engage handle levers.
Batteries need to be charged.
Troubleshoot accordingly.
Remove debris or string/twine from pads; clean
pad; replace pad.
Use more aggressive burnishing pad.
Replace pad.
Check ampere draw of burnish motor (should not
be above 50 amps); replace gas spring.
Use less aggressive burnishing pad.
Empty dust bag.
Check the dust tube to see if there is an obstruc-
tion.
Skirt is bent or damaged. Replace if necessary.
Adjust the skirt to fight tightly against the seal, but
still able to move freely.
Check wear edge on bottom of the skirt and
replace if necessary.