Operations

Over Current Protection

70A Breaker - Over current protection for the Burnish
Motor. Push to reset.
40A Breaker - Over current protection for the Traction
Drive. Push to reset.
3A Fuse In-Line holder - Over current protection for key
switch.

Onboard Battery Charger

To charge the batteries, first drive the machine to a flat,
dry, well-ventilated area then turn the machine off. If
using lead acid batteries, check the water level in all the
battery cells. If the level is low, add just enough distilled
water to cover the plates. **DO NOT OVERFILL.**
Then plug the charger cord into a wall socket. The
battery charger will initialize and then soft start the
charging cycle.
Batteries emit hydrogen gas when charging. Explosion
or fire can result. Keep sparks and open flame away
when charging.
Les batteries émettent du gaz hydrogène. Une
explosion ou un incendie peut en résulter. Maintenez
les étincelles et les flammes nues à l'écart. Gardez les
carters ouverts lors du chargement.
20
When servicing machine, wear protective gloves and
goggles. Avoid contact with battery acid.
Portez toujours des lunettes et des vêtements de
protection pour travailler sur les batteries. Évitez tout
contact avec l'acide de batterie.

Battery Charger Controls:

1. Three-digit display + symbol (1), to view
A=charging current, U=battery voltage, h=charging
time, C=charging ampere-hours (AH), E=energy
used to charge (KWh)
2. Button for the Selection of the display mode (2): A,
U, h, C, E. After 10 seconds the display returns to
the display of charging current.
3. Red control indicator (3): when it is on, the
charging cycle has started.
4. Yellow control indicator (4): when it is on, the final
phase of the charging cycle has started.
5. Green control indicator (5): when it is on, the
charging cycle has finished.
Once the charge cycle is complete, the charger will
remain active in a trickle charge mode to maintain the
charge on the batteries until the charger is unplugged
from the wall socket.