Table 5-3 Mapping between the cross-sectional area of the conductor and the value of L1
Cross-
Sectional Area
of Conductor
(mm
1 (0.002)
1.5 (0.002)
2.5 (0.004)
4 (0.006)
6 (0.009)
Step 2 Putting the cord end terminal onto the conductor, and ensure that the conductor is aligned with
the edge of the cord end terminal, as shown in
After the conductor is fed into the cord end terminal, the protruding part of the conductor must
not be longer than 1 mm (0.04 in.).
Figure 5-13 Put the cord end terminal onto the conductor
Step 3 Crimp the joint parts of the cord end terminal and the conductor, as shown in
Issue 02 (2014-12-05)
Value of L1 (mm
(in.))
2
2
(in.
))
8 (0.31)
10 (0.39)
10 (0.39)
12 (0.47)
14 (0.55)
NOTICE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Cross-Sectional
Area of Conductor
2
2
(mm
(in.
))
10 (0.015)
16 (0.025)
25 (0.039)
35 (0.054)
50 (0.077)
Figure
5-13.
5 Appendix
Value of L1 (mm
(in.))
15 (0.59)
15 (0.59)
18 (0.71)
19 (0.75)
26 (1.02)
Figure
5-14.
52