Sun StorEdge
D2 Array Cabinet Installation Guide
Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054 U.S.A.
650-960-1300
Part No. 816-1696-11
February 2002, Revision A
Send comments about this document to: docfeedback@sun.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the StorEdge D2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sun Microsystems StorEdge D2

  • Page 1 Sun StorEdge ™ D2 Array Cabinet Installation Guide Sun Microsystems, Inc. 4150 Network Circle Santa Clara, CA 95054 U.S.A. 650-960-1300 Part No. 816-1696-11 February 2002, Revision A Send comments about this document to: docfeedback@sun.com...
  • Page 2 Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, Sun StorEdge, Sun Fire, and Solaris are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc.
  • Page 3 Note – You need a Philips screwdriver to perform the procedures in this manual. Shipping Box Contents The shipping box for the cabinet-mountable (also called rack-mountable) Sun StorEdge D2 array contains the following items needed for installing the array in a Sun cabinet. Inventory for the Cabinet-mountable Sun StorEdge Array...
  • Page 4 Trim strips with four 10-14 x 7/16 in screws attached 10-14 x 7/16 in screws Overview of Tasks for Mounting Arrays lists the tasks required for mounting a Sun StorEdge D2 array in a Sun TABLE 3 cabinet along with links to where the tasks are documented.
  • Page 5 Rackmount Placement Matrix (RPM) when you are installing a Sun StorEdge D2 array. Vertical mounting space is defined in rack units (RUs). Sun StorEdge D2 arrays are 4 RU units high. One RU equals 1.75 in (4.44 cm), which is the total of the distances between the repeating pattern of the mounting holes that make up one RU: .5 in...
  • Page 6 RPM showing the mounting holes to use when TABLE 4 installing Sun StorEdge D2 arrays in a Sun StorEdge Expansion Cabinet. See the RPM for other tables that list mounting holes for installing these arrays in other qualified cabinets.
  • Page 7 Procedures To Install a Tray on an Array Use an 8 in lb torque Philips screwdriver to start the holes. Tighten the screws with an 18 in lb torque driver. Caution – This procedure requires two people to lift and move the array. Use care to avoid injury.
  • Page 8 6. With the aid of an assistant, restore the array to the upright position with the front of the array facing you. 7. Go to “To Connect the Mounting Brackets to a Cabinet” on page 7. Sun StorEdge D2 Array Cabinet Installation Guide • February 2002...
  • Page 9 To Connect the Mounting Brackets to a Cabinet Use an 8 in lb torque Philips screwdriver to start the holes. Tighten the screws with an 18 in lb torque driver. Have the Rackmount Placement Matrix table handy that applies to your cabinet. Note –...
  • Page 10 Place the top holes of the mounting bracket onto the appropriate screws on each side. iii. Slide the bracket down so that the tops of the holes rest on the screws. Sun StorEdge D2 Array Cabinet Installation Guide • February 2002...
  • Page 11 4. Loosely thread four more 10-32 x 1/2 in screws through the appropriate bottom holes of the mounting brackets into the designated holes in the rails. Bottom holes for Sun Fire cabinets Bottom holes for Sun Fire cabinets Cabinet Back Cabinet Front Right Left...
  • Page 12 3. Align the mounting tray with the mounting brackets in the cabinet ( FIGURE 6 Back Front Aligning the Mounting Tray With the Mounting Brackets FIGURE 6 Sun StorEdge D2 Array Cabinet Installation Guide • February 2002...
  • Page 13 4. Rest the array on the mounting brackets. 5. Slide the array into the cabinet. 6. Insert and tighten two 10-32 x 1/2 in screws in the designated holes to connect the back of the tray to the rails at the back of the cabinet ( FIGURE 7 For example, when installing the first array into a Sun StorEdge expansion cabinet, you would insert the two screws through the back of the tray into holes 11 and 14 on...
  • Page 14 11 and 14 on the rails at the front of the cabinet ( FIGURE 8 Hole 14 Hole 11 Example: Connecting the Front of the First Tray to the Cabinet FIGURE 8 Sun StorEdge D2 Array Cabinet Installation Guide • February 2002...
  • Page 15 8. Place one trim strip at the right and another trim strip at left side of the front of the array, and insert and tighten the attached screws into the matching holes in the rails at the front ( FIGURE 7 shows the trim strip being applied after the screws connecting the tray to FIGURE 7 the front of the cabinet.
  • Page 16 Sun StorEdge D2 Array Cabinet Installation Guide • February 2002...