2.1.2

SCSI Cables

The maximum SCSI bus length is 12 meters (472 inches). Exceeding this length can
cause SCSI or data errors. When calculating the maximum SCSI bus length in a
particular configuration, remember to include the internal SCSI bus of each Sun
StorEdge D2 device, which is 0.1 meter.
Note – For the most recent listing of supported SCSI cables, sizes, and part
numbers, refer to the Sun StorEdge D2 Array Release Notes.
2.2
Cluster and Multi-Initiator
Configurations
This section contains the following topics:
Section 2.2.1, "Cluster Information" on page 2-2
Section 2.2.2, "Multi-Initiator Information" on page 2-3
2.2.1

Cluster Information

Note – Sun Cluster 3.0 software support for the Sun StorEdge D2 array is currently
under qualification and anticipated for availability in Q402. Sun Cluster 2.2 software
is not supported for the Sun StorEdge D2 array.
The Sun Cluster home page is located on the following web site:
http://suncluster.eng/index.html
For detailed cluster configuration information, refer to the Sun Enterprise Cluster
System Hardware Site Preparation, Planning, and Installation Guide. You can find this
document on the following web site:
http://suncluster.eng.sun.com/engineering
Refer to the following document for specific information on clustering arrays: Sun
Cluster 3.0 Hardware Guide, 806-1420, chapter 7 "Installing, Configuring, and
Maintaining a Sun StorEdge Disk Array."
2-2
Sun StorEdge D2 Array Best Practices Guide • January 2002