6
C H A P T E R
SAF-TE Command Implementation
SCSI Accessed Fault-Tolerant Enclosures (SAF-TE) support six SCSI commands
including WRITE BUFFER, READ BUFFER, INQUIRY, TEST UNIT READY, SEND
DIAGNOSTIC, and REQUEST SENSE. These commands are detailed in the following
sections:
Section 6.1, "Inquiry command" on page 6-1
Section 6.2, "SAF-TE Read Buffer Commands" on page 6-3
Section 6.3, "SAF-TE Write Buffer Commands" on page 6-9
6.1
Inquiry command
The host uses the
enclosure. The table below shows the response data format from the
command.
TABLE 6-1
Byte
0
1
2
command to request parameter information from the
INQUIRY
I
Data
NQUIRY
Bit
Description
7-5
Peripheral Qualifier
4-0
Peripheral Qualifier
7-0
00h
7-3
0
INQUIRY
Returned Value/ Notes
000b if LUN 0 (the only valid) is
selected
011 if LUN 0 is not selected
03h (SCSI Processor Device) if
LUN 0 (the only valid LUN) is
selected 1Fh (No device type) if
LUN 0 is not selected
Returns 00h
0
6-1
Need help?