Sign In
Upload
Manuals
Brands
Siemens Manuals
Medical Equipment
MAMMOMAT 300
Siemens MAMMOMAT 300 Manuals
Manuals and User Guides for Siemens MAMMOMAT 300. We have
3
Siemens MAMMOMAT 300 manuals available for free PDF download: Installation And Start-Up Instructions Manual, Repair Instructions, Parts Replacement
Siemens MAMMOMAT 300 Installation And Start-Up Instructions Manual (93 pages)
Brand:
Siemens
| Category:
Medical Equipment
| Size: 0.66 MB
Table of Contents
Table of Contents
2
1 Prerequisites
6
Meters and Appliances, Tools, Notes
6
Meters and Appliances Required
6
Tools Required
6
Start-Up, DHHS and X-Ray Decree Area of Application
7
Important Notes on Start-Up
7
Checking and Recording for the Area of Application of the X-Ray Decree (§16 Germany)
7
Checking and Recording for the DHHS Area of Application
8
Note on Delivery State
8
2 Protective Measures
10
3 Preparatory Work
12
General
12
Scope of Delivery
12
Unpacking the Stand
13
Unpacking
13
Removing the Transport Safeguards
14
Removing the Swivel-Arm System Transport Safeguard
14
Transport Safeguard for the Lifting Carriage
14
Transport Safeguard for the Rotary Motion
15
Protective Strips for the Metal Curtain
15
Unpacking the Generator and Mounting the Radiation Field
16
4 Installing the Generator and the Stand
18
Arranging the Components
18
Removing the Generator Cover
19
Installing the Cable Ducts
20
Laying the Cable Harness
21
Aligning the Stand
22
5 Cable Connections
24
EMC Measures
24
EMC Measures at the Cable Entry
24
Fitting the Hose Clamps and Ferrite Sleeves
24
EMC Measures on the Bottom Plate
26
Fitting the Cables X1, X8 and X9 on the Bottom Plate
26
Connecting the Stand Cable-Harness
27
The High-Voltage Connectors, Alternative Types
27
Connecting the High-Voltage Connector
28
Connecting the Cable Harness to the Generator
29
Mains Connection
31
Connecting the Incoming Mains to the Stand (400 V, 2-Phase)
31
400 V 2-Phase Connection
31
Connecting the Mains Supply to the Generator
32
Measures for Changing from 2-Phase to 1-Phase Connection
33
6 Modifying the Object Tables
34
7 Mains Connection and Power Supply
36
Checks before Powering up the Generator
36
Measuring the Line Resistance
36
Checking the Line Voltage in the Generator
37
Checking the Supply Voltages
38
8 Attaching the Swivel-Arm Covers
40
Arranging the Swivel-Arm System
40
Connecting the Cables to Control-Button Board and Patient Handles
40
Attaching the Covers
41
9 Checking the Microprocessors
42
Microprocessors
42
10 Checks Without High Voltage
44
11 Checks with High Voltage
46
Preparation
46
Mas Values
46
Tube Current Reduction
47
Oscilloscope Diagrams
48
12 Start-Up and Functional Test of the IONTOMAT
52
Checking and Programming with the Service PC
52
Sensitivity
52
Sensitivity Correction
53
Correction Curve
53
Other Film/Screen Combinations
54
Correction Curve Diagrams
55
Checking the Film Density
59
Checking the Automatic Transparency Adaption
60
Checking Cut-Off Dose and Resolution (§16 Germany)
61
Output Values of Constancy Testing (§16 Germany)
62
13 Further Programming
64
Setting the Real Time Clock
64
Prerequisite
64
Setting the Time in the Mammomat
64
Setting the Tube-Current Reduction
64
Reducing the Generator Power
65
14 Checking the Swivel-Arm System
66
Rotary Motion
66
Vertical Adjustment
67
Emergency Stop
68
15 Field Light
70
Checking and Adjusting the Field Light Time
70
Checking the Field Light Time
70
Adjusting the Field Light Time
71
16 Checking the Compression Device and OPCOMP
72
Checking the Compression Device
72
Checking the OPCOMP
74
17 Checking the Exposure Blocking
76
18 Checking the Radiation Field Limitation
78
General
78
Measuring Procedure
78
19 Final Procedures
80
Service PC and Measuring Instruments
80
Recording the Programmed Values
80
Reading the Exposure Counter and Deleting the Error Memory
80
Removing the Measuring Instruments
81
Checking the Protective Grounding Resistance
81
Mounting the Cable Duct Covers
81
Mounting the Stand Covers
82
Mammomat Stand with Separate Rear Side Covers
82
Fitting the Cable Outlet Cover
84
Mounting the Front Cover Onto the Generator
84
Final Protective Grounding Resistance Test
85
Face Shield
85
Warning Label on Control Panel
86
20 Options
88
Bolting the Stand/Generator to the Floor
88
21 Appendix
90
Working with the Service PC
90
Description of the Syntax Used in These Instructions
90
Connecting the Service PC
91
Measuring Protocol
92
Advertisement
Siemens MAMMOMAT 300 Repair Instructions (46 pages)
Brand:
Siemens
| Category:
Medical Equipment
| Size: 0.99 MB
Table of Contents
Table of Contents
3
Systems Affected
5
Documents Required
5
Tools and Measurement Devices Required
5
Parts Required
5
Time Required
5
Differences between MAMMOMAT 300 / MAMMOMAT 3000
5
Safety Information
6
Removing the Stand Covers
7
MAMMOMAT Stand with Separate Rear Side Covers
7
MAMMOMAT with Single Rear Cover
8
Removing the Swivel Arm Cover
9
Removing the Compression Unit
10
Removing Other Components
12
MAMMOMAT 3000 / MAMMOMAT 3000 CE Only
13
Remove the Connectors at the MAMMOMAT 300/300 CE Swivel Arm
15
Remove the Connectors at the MAMMOMAT 3000/3000 CE Swivel Arm
16
All Mammomats: Removing the High Voltage Cable
18
MAMMOMAT 300/300 CE Only - Removing the Corrugated Hose
19
MAMMOMAT 3000/ 3000CE Only - Removing the Corrugated Hose
20
All Mammomats: Additional Disassembly Work
21
All Mammomats: Removing the Cable Harness from the Left Side of the Stand
22
On the Left Side of the Stand Remove
23
MAMMOMAT 3000 CE Only
23
All Mammomats: Disconnecting the Cable Harness at the Back Wall of the Stand
24
Removing the Connectors on the Left Side of the Stand
25
MAMMOMAT 300 CE and MAMMOMAT 3000 CE Only
26
Removing the Cable Harness from the Stand
27
Removing the Cable Harness at the Generator
28
MAMMOMAT 300 / MAMMOMAT 3000 Only
29
All Mammomats
29
Rerouting the Wires
30
Routing the Cable Harness
31
Connecting the Cable Harness to the Left Side of the Stand
33
Connecting the Cable Harness to the Back Wall of the Stand
34
If the Swivel Motor Has Been Removed
35
MAMMOMAT 300 CE / MAMMOMAT 3000CE Only
35
Mammomat 300/ Ce
37
Mammomat 3000/ Ce
38
Mammomat 300/ Ce
39
Mammomat 3000/ CE
40
Installing X891 and X893
41
Connecting the STOP Switch
41
Routing the Cable in the Swivel Arm
42
Correct Positioning of the Compression Unit
43
Siemens MAMMOMAT 300 Parts Replacement (20 pages)
Compression Mechanism and Potentiometer R863
Brand:
Siemens
| Category:
Medical Equipment
| Size: 0.48 MB
Table of Contents
Table of Contents
3
General
5
Components Concerned
5
Tools Required
5
Documents Required
5
Parts Included
6
Time Required
6
Remove the Covers from Compression Unit
7
Replace the Compression Mechanism
8
Test the Compression Function
11
Exchange of Potentiometer
13
Work Steps
13
Advertisement
Advertisement
Related Products
Siemens MAMMOMAT NovationDR
Siemens MAMMOMAT Novation SP
Siemens MAMMOMAT 3000
Siemens MAMMOMAT Balance
Siemens MAMMOMAT Novation DR
Siemens MAMMOMAT 1000
Siemens MAMMOMAT 3000 Modular
Siemens MAMMOMAT Nova Opdima 1000
Siemens MAMMOMAT Nova Opdima 3000
Siemens MAMMOMAT Inspiration
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL