Sign In
Upload
Manuals
Brands
METREL Manuals
Multimeter
MI 3122
METREL MI 3122 Manuals
Manuals and User Guides for METREL MI 3122. We have
1
METREL MI 3122 manual available for free PDF download: Instruction Manual
METREL MI 3122 Instruction Manual (59 pages)
Z Line-Loop / RCD
Brand:
METREL
| Category:
Multimeter
| Size: 0.7 MB
Table of Contents
Instruction Manual
1
Table of Contents
3
1 Preface
5
2 Safety and Operational Considerations
6
Warnings and Notes
6
Battery and Charging
8
New Battery Cells or Cells Unused for a Longer Period
9
Standards Applied
10
3 Instrument Description
11
Front Panel
11
Connector Panel
12
Back Site
13
Display Organization
14
Terminal Voltage Monitor
14
Battery Indication
14
Message Field
14
Result Field
15
Sound Warnings
15
Help Screens
15
Backlight and Contrast Adjustments
16
Instrument Set and Accessories
17
Standard Set
17
Optional Accessories
17
4 Instrument Operation
18
Function Selection
18
Settings
19
Language
19
Initial Settings
20
Memory
21
Date and Time
21
RCD Standard
21
Isc Factor
23
Commander
23
5 Measurements
24
Testing Rcds
24
Contact Voltage (RCD Uc)
25
Trip-Out Time (Rcdt)
26
Trip-Out Current (RCD I)
27
RCD Autotest
27
Fault Loop Impedance and Prospective Fault Current
30
Line Impedance and Prospective Short-Circuit Current
32
Voltage, Frequency and Phase Sequence
34
PE Test Terminal
36
6 Data Handling
38
Memory Organization
38
Data Structure
38
Storing Test Results
40
Recalling Test Results
40
Clearing Stored Data
42
Clearing Complete Memory Content
42
Clearing Measurement(S) in Selected Location
42
Clearing Individual Measurements
43
Communication
44
7 Maintenance
45
Cleaning
45
Periodic Calibration
45
Service
45
8 Technical Specifications
46
RCD Testing
46
General Data
46
Contact Voltage RCD-Uc
46
Trip-Out Time
47
Trip-Out Current
47
Fault Loop Impedance and Prospective Fault Current
47
No Disconnecting Device or FUSE Selected
47
RCD Selected
48
Line Impedance and Prospective Short-Circuit Current
48
Voltage, Frequency, and Phase Rotation
49
Phase Rotation
49
Voltage
49
Frequency
49
Online Terminal Voltage Monitor
49
General Data
50
A Appendix A - Fuse Table
51
Fuse Table - IPSC
51
Fuse Table - Impedances (UK)
53
Fuse Table - Impedances at 230 V A.C. (AS/NZS 3017)
54
B Appendix B - Accessories for Specific Measurements
56
C Appendix C - Country Notes
57
List of Country Modifications
57
Modification Issues
57
AUS / NZ Modification - Fuse Types According to AS/NZS 3017
57
Advertisement
Advertisement
Related Products
METREL MI 3125B
METREL MD 9020
METREL MD 9070
METREL MD 9035
METREL MD 9016
METREL MD 9040
METREL MD 9050
METREL MD 9880
METREL MD 9030
METREL MD 9055
METREL Categories
Measuring Instruments
Test Equipment
Multimeter
Adapter
Motherboard
More METREL Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL