Sign In
Upload
Manuals
Brands
Fire-Lite Alarms Manuals
Controller
MRP-2001
Fire-Lite Alarms MRP-2001 Manuals
Manuals and User Guides for Fire-Lite Alarms MRP-2001. We have
1
Fire-Lite Alarms MRP-2001 manual available for free PDF download: Installation, Operation, And Programming Manual
Fire-Lite Alarms MRP-2001 Installation, Operation, And Programming Manual (136 pages)
deluge preaction control
Brand:
Fire-Lite Alarms
| Category:
Controller
| Size: 2.22 MB
Table of Contents
Fire Alarm System Limitations
2
Installation Precautions
3
Table of Contents
4
SECTION 1: Product Description
11
Product Features
11
Specifications
13
Controls and Indicators
14
Components
15
Optional Modules and Accessories
16
SECTION 2: Installation
17
Backbox Mounting
17
Operating Power
20
Input Circuits
21
Output Circuits
23
1: Outputs/Notification Appliance/Releasing Circuits
23
2: Special Application DC Power Output Connections
24
3: Relays - Programmable
24
Power-Limited Wiring Requirements
25
Installation of Optional Modules
26
1: CAC-5X Class a Converter Module
26
Installation
26
Wiring Nacs and Idcs for Class a
27
2: 4XTMF Municipal Box Transmitter Option Module
28
4XTMF Transmitter Module Installation
29
ANN-BUS Devices
30
1: ANN-BUS Wiring
30
Calculating Wiring Distance for ANN-BUS Modules
30
Wiring Configuration
32
Powering ANN-BUS Devices from Auxiliary Power Supply
33
2: ANN-BUS Device Addressing
33
3: ANN-80 Remote LCD Annunciator
34
4: Specifications
34
5: Installation
34
Mounting
34
Opening/Closing Annunciator
34
Wiring ANN-80 to FACP
35
6: ANN-S/PG Serial/Parallel Printer Interface Installation
37
Printer Installation
37
Specifications
37
Connecting PRN-6 Printer
38
Setting Printer Options
38
7: ANN-I/O LED Driver Module
39
ANN-I/O Board Layout
39
Specifications
39
ANN-I/O Connection to FACP
40
ANN-I/O Module LED Wiring
41
8: ANN-LED Annunciator Module
41
ANN-LED Board Layout
42
Mounting/Installation
42
Specifications
42
ANN-LED Connection to FACP
43
9: ANN-RLY Relay Module
44
ANN-RLY Board Layout
44
Mounting/Installation
44
Specifications
44
ANN-RLY Connection to FACP
45
SECTION 3: Programming
46
User Programming
46
Initial Power-Up
47
Programming Screens Description
47
Programming and Passwords
48
Master Programming Level
49
1: FACP CONFIG (Application Templates)
50
2=Input Zones
50
3=Output Circuits
57
Enabled
58
Release Circuit 1 or Release Circuit 2
58
Type
58
Release Stage NAC
59
Silence
59
Auto Silence
60
Silence Inhibited
60
Coding
61
Synchronized NAC Operation
62
4: Cross Input Zones
63
5: On-Board Relays
64
6: System Setup
64
Timers
65
Soak 1 or Soak 2
66
Waterflow Delay
66
AC Loss Delay
67
Banner
67
Time-Date
68
Clock Format
69
Date
69
Time
69
Charger Disable
70
Daylight Savings Time
70
Trouble Reminder
70
7: Ann-Bus
71
ANN-BUS Enabled
71
ANN-BUS Modules
72
Ann-S/Pg Options
73
Auto-Configure
73
ANN-I/O LED Zone Assignments
75
Options
76
ANN-RLY Options
77
8: History
78
Erase History
78
View Events
78
9: Walktest
79
10: Clear Program
80
11: Password Change
80
Maintenance Programming Level
81
1: Input Zones - Enable/Disable
82
2=History
82
3=Walktest
83
4: Time-Date
84
SECTION 4: Operating Instructions
85
Panel Control Buttons
85
1: Acknowledge/Step
85
2: Alarm Silenced
85
3: Drill/Hold 2 Sec
85
4: Reset
85
Indicators
86
Normal Operation
86
Trouble Operation
87
Alarm Operation
88
Supervisory Operation
89
Disable/Enable Operation
89
Waterflow Circuits Operation
89
2Nd-Shot Water Switch
90
Detector Functions
90
Time Functions: Real-Time Clock
90
Coded NAC Operation
90
Release Stages
91
Special System Timers
91
1: Silence Inhibit Timer
91
2: Autosilence Timer
91
3: Trouble Reminder
91
4: Soak Timers
91
5: Waterflow Delay Timer
91
Walktest
91
Read Status
92
2=Input Zones
92
1: FACP Configuration
93
3=Output Circuits
94
4: Cross Input Zones
94
5: On-Board Relays
95
6: System Settings
95
7: Timers
96
8: Daylight Savings
96
10: Ann-S/Pg
97
9: History
97
11: Ann-Bus
98
SECTION 5: Power Supply Calculations
99
Overview
99
Calculating the AC Branch Circuit
99
Calculating the System Current Draw
100
1: Overview
100
2: How to Use Table 5-3 on Page 101 to Calculate System Current Draw
100
Calculating the Battery Size
102
1: NFPA Battery Requirements
102
2: Selecting and Locating Batteries
102
APPENDIX A Circuit Mapping and Cross-Zoning
103
A.1: Input-To-Output Circuit Mapping and Cross-Zone Operation
103
A.1.1: Mapping Input Zones to Output Circuits for Direct Activation
104
A.1.2: Mapping Input Zones to Release Circuits for Cross Zone
105
Activation
105
Release Circuits
107
APPENDIX Bfacp Configuration Templates
108
B.1: Template 7: Single Hazard - 3 Zone
109
B.2: Template 8: Single Hazard - Cross-Zone with Manual Release
110
B.3: Template 9: Dual Hazard - Combined Release
111
B.4: Template 10: Dual Hazard - Split Release
112
B.5: Template 11: Single Hazard - 3 Zones and Low Pressure
113
B.6: Template 12: Single Hazard - 2 Zones Cross-Zoned with All Active
114
B.7: Template 13: Single Hazard - Dual Zone
115
APPENDIX Cnfpa Standard-Specific Requirements
116
C.1: NFPA 72 Auxiliary Fire Alarm System
119
C.2: Central Station/Remote Station Transmitter Connection to FACP Dry Contacts
122
Connection to FACP Dry Contacts
122
APPENDIX D: FACP with Keltron
123
APPENDIX E: Testing & Maintenance
124
E.1: Testing
124
3: Detector Testing
124
E.1.1: Inspection
124
E.1.2: Alarm Test
124
E.2: Maintenance
125
Limited Warranty
135
Advertisement
Advertisement
Related Products
Fire-Lite Alarms MRP-2001E
Fire-Lite Alarms MRP-4424
Fire-Lite Alarms MS-9600LSE
Fire-Lite Alarms MS-10UD Series
Fire-Lite Alarms MS-5UD Series
Fire-Lite Alarms MS-4412B
Fire-Lite Alarms MS-5210UD
Fire-Lite Alarms MS-4424BE
Fire-Lite Alarms MS-5012
Fire-Lite Alarms MS-9200E
Fire-Lite Alarms Categories
Smoke Alarm
Control Panel
Fire Alarms
Accessories
Power Supply
More Fire-Lite Alarms Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL