Sign In
Upload
Manuals
Brands
ASD Manuals
Measuring Instruments
FieldSpec 3
ASD FieldSpec 3 Manuals
Manuals and User Guides for ASD FieldSpec 3. We have
2
ASD FieldSpec 3 manuals available for free PDF download: User Manual
ASD FieldSpec 3 User Manual (110 pages)
Brand:
ASD
| Category:
Measuring Instruments
| Size: 8 MB
Table of Contents
Trademark Information
2
Table of Contents
3
Technical Support
2
Chapter 1 Introduction
11
Hardware Specifications
12
Physical Specifications
12
Power Input and Output
13
Fieldspec Wavelength Configuration
13
Interface Requirement
14
Standard Accessories
15
Computer Requirements
16
Software Requirement
16
Theory of Operation
17
Chapter 2 Setup
21
Unpacking the Instrument
21
Power Supply
24
Ethernet Cables
26
Accessory Power Port
27
Pistol Grip
28
External Trigger
31
Laptop Carrier (Belly Board)
33
Chapter 3 Usage and Maintenance
37
Light Sources
37
Access and Ventilation
37
Cleaning
38
Annual Maintenance
38
Returning Instrument to ASD for Service
38
Chapter 4 Fiberoptic Interface
39
Fiberoptic Cables
39
LED Check for Fiberoptic Cable
40
Fore Optic Discussion
43
Chapter 5 Batteries
47
Battery Care
47
Battery Charger
48
Application Battery Indicator
49
Transporting and Carrying the Fieldspec
51
Packing Fieldspec® 3 for Shipment
51
Chapter 6 Transporting and Carrying the Fieldspec® 3
53
Preparing the Fieldspec® 3 and Ergonomic Pro-Pack for the Field
56
Carrying Supplies
62
Protecting the Instrument in the Field
63
Chapter 7 Field Measurements
65
Illumination
66
Characteristics of Natural Illumination
66
Characteristics of Artificial Illumination
68
Atmospheric Characteristics
68
Clouds
70
Wind
71
Vegetation
71
Rocks, Soils, and Man-Made Materials
74
Experimental Design
75
Time of Day / Year
75
Sampling Strategy
75
Viewing Geometry
76
Suggested Set-Up
76
RS3 Application
76
Indico Application
77
White Reference
79
Spectralon Reflectance Data
79
Maintaining Spectralon References
80
White Reference Procedures
81
Appendix A Troubleshooting
83
Common Communication Fixes
83
Does Not Connect to the Spectrometer
83
Does Not Connect Wireless
85
Does Not Connect to the Access Point
87
Spectrometer Loses Its Wireless Connection
88
Wireless Interface Is Disabled in the Netcfg Application
88
Appendix B Reference Information
91
Frequently Asked Questions (FAQ)
91
What Is a Spectroradiometer
91
What Are the Differences between the ASD Spectrometers
92
What Is Remote Sensing
92
How Often Do I Need to Optimize
93
How Often Do I Need a (Baseline) White Reference
93
What Spectrum Average (or Sample Count) Should I Use
93
What if I Want to Keep the same Settings All Day
94
When Do I Use Absolute Reflectance
94
How Do I Know the Field-Of-View that I'M Using
94
B.1.10 What Are the Units of Radiance
95
B.1.11 Can I Post-Process My Data
96
B.1.12 Why Do I See Oscillations (Sine Wave) in My Data
96
B.1.13 What Are These Two Large Noise Bands in My Data
96
What Are These Upward or Downward Spikes in VNIR Data
97
B.1.15 What Are These Steps in My Data
97
B.1.16 What Can Cause more Noise in My Data from Last Time
98
Why Does the VNIR Drop to Zero after a Dark Current Collection
98
How Do I Collect a Reference with a Spot Size Larger than the Spectralon Panel
98
B.1.19 How Do I Set up GPS
98
B.1.20 What Does a Broken Fiber Mean
99
B.1.21 How Long Is the Battery Life
100
What Type of Ethernet Cable Can I Use for the Static IP Configuration
101
Can I Install Additional Software on the Instrument Controller
101
B.1.24 Why Does the Software Seem to Do Unexpected Things
101
How Long Does It Take for the Fieldspec Spectroradiometer to Warm up
102
B.1.26 Where Is My Serial Number
102
Data Conversion
102
Gain and Offset
102
Light Source
103
Optimization
103
Spectral Discontinuities
104
Field-Of-View
104
White Reference
105
Other Tips on Discontinuities
105
Spectrum Averaging (or Sample Count)
105
Temperature Effects
106
Technical Support
106
W.E.E.E. Compliance
107
Index
109
Advertisement
ASD FieldSpec 3 User Manual (98 pages)
Brand:
ASD
| Category:
Measuring Instruments
| Size: 2 MB
Table of Contents
Trademark Information
2
Table of Contents
3
Technical Support
2
Declaration of Conformity
7
Chapter 1 Introduction
9
Hardware Specifications
10
Physical Specifications
10
Power Input and Output
10
Fieldspec® 3 Spectroradiometer Wavelength Configuration
11
Interface Requirement
12
Standard Accessories
12
Computer Requirements
13
Software Requirement
13
Theory of Operation
14
Chapter 2 Setup
19
Unpacking the Instrument
19
Power Supply
22
Ethernet Cables
24
Accessory Power Port
25
Pistol Grip
26
External Trigger
27
Belly Board
28
Chapter 3 Usage and Maintenance
31
Light Sources
31
Operate Safely
31
Changing Bulbs
31
Access and Ventilation
32
Cleaning
32
Annual Maintenance
32
Rma
33
Chapter 4 Fiber Optic Interface
35
Fiber Optics Cables
35
LED Check for Fiber Optic Cable
36
Fore Optic Discussion
39
Chapter 5 Batteries
43
Battery Care
43
Battery Charger
44
RS Battery Indicator
45
Chapter 6 Transporting and Carrying the Fieldspec® 3 Spectroradiometer
47
Packing Fieldspec® 3 Spectroradiometer for Shipment
47
Preparing the Fieldspec® 3 Spectroradiometer and Ergonomic Pro-Pack for the Field
52
Carrying Supplies
57
Protecting the Instrument in the Field
58
Chapter 7 Field Measurements
61
Illumination
62
Characteristics of Natural Illumination
62
Characteristics of Artificial Illumination
63
Atmospheric Characteristics
64
Clouds
66
Wind
67
Vegetation
67
Rocks, Soils, and Man-Made Materials
70
Experimental Design
70
Time of Day / Year
70
Sampling Strategy
70
Viewing Geometry
71
Suggested Set-Up
71
White Reference
73
Spectralon Reflectance Data
74
Maintaining Spectralon References
75
White Reference Procedures
76
Appendix A Troubleshooting
77
Common Communication Fix
77
Does Not Connect to the Spectrometer
77
Can't Get a Wireless Connection
79
Does Not Connect to the Access Point
80
Spectrometer Loses Its Wireless Connection
81
Wireless Interface Is Disabled in the Netcfg Application
81
Appendix B Reference Information
83
Frequently Asked Questions (FAQ)
83
How Often Do I Need to Optimize
83
How Often Do I Need a White Reference (WR)
83
What Spectrum Average Should I Use
84
What if I Want to Keep the same Integration Time, Gain Value, and Offset Value for the Entire Day
84
When Do I Use Absolute Reflectance
84
How Do I Know the Field of View that I'M Using
84
What Are the Units of Radiance
85
Can I Post-Process My Data
85
Why Do I See Oscillations (Sine Wave) in My Data
86
What Are These Large Noise Bands in My Data at 1400Nm and 1800Nm
86
What Are These Upward or Downward Spikes in VNIR Data
86
B.1.12 What Are These Steps in My Data
86
What Can Cause more Noise in My Data than When I Previously Used the Instrument
87
Why Does the VNIR Drop to Zero after a Dark Current Has Been Collected
87
How Do I Collect a Reference When My Spot Size Is Larger than the Spectralon Panel
87
B.1.16 How Do I Clean My Spectralon Panel
87
B.1.17 How Do I Set up GPS
88
B.1.18 What Does a Broken Fiber Mean
89
B.1.19 How Long Is the Battery Life
90
What Type of Ethernet Cable Can I Use for the Static IP Configuration
90
Can I Install Additional Software on the Instrument Controller
90
B.1.22 Why Does the Software Seem to Do Strange Things
91
B.1.24 Where Is My Serial Number
91
ASCII Conversion
91
Gain and Offset
92
Light Source
92
Optimization
93
Spectral Discontinuities
93
Field of View
94
White Reference
94
Other Tips on Discontinuities
94
Spectrum Averaging
95
Temperature Effects
95
Technical Support
95
Index
97
Advertisement
Related Products
ASD FieldSpec 4
ASD A100800
ASD A100810
ASD A100820
ASD TerraSpec
ASD Categories
Outdoor Light
Lighting Equipment
Measuring Instruments
Automatic Barriers
Flood Light
More ASD Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL