Other Functions - Daikin 2MXS-N Series Service Manual

Hide thumbs Also See for 2MXS-N Series:
Table of Contents

Advertisement

SiUS121502E

1.14 Other Functions

1.14.1 Hot-Start Function
In order to prevent the cold air blast that normally occurs when heating operation starts, the
temperature of the indoor heat exchanger is detected, and the airflow is either stopped or
significantly weakened resulting in comfortable heating.
Note:
The cold air blast is prevented using similar control when defrost control starts or when the
thermostat is turned ON.
1.14.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal receiving
sound.
1.14.3 Indoor Unit ON/OFF Button
An ON/OFF button is provided on the display of the unit.
Ex: CTXS, FTXS series
1.14.4 Auto-restart Function
If a power failure (including one for just a moment) occurs during the operation, the operation
restarts automatically when the power is restored in the same condition as before the power failure.
Note:
It takes 3 minutes to restart the operation because the 3-minute standby function is activated.
Function and Control
Press the ON/OFF button once to start operation. Press once again to stop it.
The ON/OFF button is useful when the remote controller is missing or the battery has run out.
Operation mode
Temperature setting
AUTO
In the case of multi system operation, there are times when the unit does not activate with this
button.
Function of CTXS, FTXS, CDXS, FDXS, FVXS Series
25°C (77°F)
ON/OFF button
Airflow rate
Automatic
(R22266)