Daikin 2MXS-N Series Service Manual page 219

Hide thumbs Also See for 2MXS-N Series:
Table of Contents

Advertisement

SiUS121502E
FTXS15/18/24LVJU
PCB3
S49
S46
1
BLK
LED1
BLK
H1P
BLK
BLK
LED2
BLK
H2P
BLK
BLK
LED3
BLK
H3P
9
BLK
SW1
S21
RTH1
BZ
R1T
S25
BLK
1
PCB4
BLK
S36
3
BLK
INTELLIGENT EYE
SENSOR
S48
PCB2
WIRELESS
REMOTE
CONTROLLER
SIGNAL
RECEIVER
Note:
PCB1: Control PCB
PCB2: Signal receiver PCB
PCB3: Display PCB
PCB4: INTELLIGENT EYE sensor PCB
Refer to Part 3 for Printed Circuit Board Connector Wiring Diagram.
Appendix
PCB1
1
~
C102
V1
C101
TRANSMISSION
9
HA
1
S47
S32
S41
4
1
3
1
2
16
8
10
12
14
2 5
3
1
3
R2T
MSW
MSW
M1S
M2S
FU1
F1U
H1
3.15A
H2
MR10
H3
CIRCUIT
FG
FU2
S1
F2U
7
RED
3.15A
4
BLU
BRN
MS
~
ORG
3
1
WHT
M1F
4
6
15
13
11
9
7
1
INDOOR
MSW
M3S
Wiring Diagrams
X1M
BLK
1
WHT
2
3
RED
GRN
FIELD WIRING.
/
GRN
YLW
CAUTION
NOTE THAT OPERATION WILL RESTART
AUTOMATICALLY IF THE MAIN POWER SUPPLY
IS TURNED OFF AND THEN BACK ON AGAIN.
BZ
: BUZZER
C101, C102
: CAPACITOR
FG
: FRAME GROUND
F1U, F2U
: FUSE
H1P~H3P
: PILOT LAMP
MR10
: MAGNETIC RELAY
M1F
: FAN MOTOR
M1S~M3S
: SWING MOTOR
PCB1~PCB4
: PRINTED CIRCUIT BOARD
R1T, R2T
: THERMISTOR
S1~S49
: CONNECTOR
SW1
: OPERATION SWITCH
V1
: VARISTOR
X1M
: TERMINAL STRIP
: PROTECTIVE GROUND
1
2
3
OUTDOOR
C: 3D060942R
207

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3mxs-n series4mxs-n series

Table of Contents