6.
Select events that cause email messages to be sent to all addresses in the
group. The following events can be monitored for this purpose:
•
Alarm Input Activation and Alarm Input Deactivation. This re-
fers to the triggering and resetting of the DVXi alarm inputs, as con-
figured in MasterControl. Select which alarm inputs are monitored
by DVXNotify.
•
Video Signal Lost and Video Signal Restored. Select which cam-
era inputs are monitored for video signal loss by DVXNotify.
•
Scene Lost and Scene Restored. Select which camera inputs are
monitored for scene loss by DVXNotify.
•
Motion Events. Select which camera inputs are monitored for mo-
tion events by DVXNotify. Also select Frames Per Event (the num-
ber of motion images required to trigger the alarm output) and Event
Timeout (the number of motionless seconds required to restart the
count of motion images).
•
Other Events. Select from several other events or actions for
DVXNotify to monitor, including MasterControl startup or exit; sys-
tem restart; recording start or stop; and successful or failed login.
Now you can configure how often and which days email can be sent to each ad-
dress in the group. To do this, select the email address in the Email Settings list
and configure the following settings:
1.
Select the Frequency to determine how often email messages can be sent
to the address. Following are the Frequency options:
•
Real-time Email—an email sent for each occurrence of a selected
condition or action
•
1 Email/Minute—an email sent at the completion of every minute
•
1 Email/Hour—an email sent at the completion of every hour
•
1 Email/3 Hours—an email sent every three hours (midnight, 3 a.m.,
6 a.m., and so on)
•
1 Email/6 Hours—an email sent every six hours (midnight, 6 a.m.,
noon, and 6 p.m.)
•
1 Email/Day (Noon)—an email sent every day at noon
125