Now when a motion event occurs on the selected camera for the specified number
of consecutive images, the alarm output is triggered for the specified Minimum
Latch Time or for the duration of the motion event, whichever is longer.
The MotionAlarm plug-in also offers the following features:
All changes entered on the MotionAlarm tab are applied immediately. To close
the Plugin Properties window, click Done.
122
4.
Select the number of Consecutive Motion Frames that must occur on that
camera input to activate the output trigger.
5.
Select the Minimum Latch Time—the minimum amount of time, in sec-
onds, for the alarm output to be activated when the consecutive motion
frames threshold is reached.
6.
Set a schedule for the camera input to be monitored by the plug-in, or
select Always On.
7.
Click Activate to initiate monitoring of the camera input.
Reset Alarm Output—deactivates the alarm output by returning it to its
normally open state. Use this if the latch time is disabled or if you want to
acknowledge an alarm before the latch time expires.
Disable Latch Time—causes the normally open alarm output to latch
indefinitely when triggered. To deactivate the alarm output, click Reset
Alarm Output.