HOST CONFIGURATION STRINGS
A
HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration
using serial strings sent from the Host.
The device configuration can be changed by receiving commands from the Host
through the serial interface. When this method is used, the programming sequence
format is the following:
$+
Command
Enter configuration environment
Example:
Multiple command programming sequence:
BG1
BH0
$+
Enter configuration environment
Each configuration parameter setting removes the condition previously active for that
parameter.
The device buffer can contain about 400 characters. If your
programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.
NOTE
This method requires the RS232 interface.
$-
Character sequence in following tables
AC410132
$-
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
Beeper tone 1
Beeper low intensity
CR
Carriage return character (0D Hex.)
Exit and Save configuration
CR
Carriage return character (0D Hex.)
Exit and save new configuration