REFERENCES
5.10 C-GRYPHON™ CONFIGURATION
Battery selection is required only when the Gryphon™ Mx30 reader has an Alkaline
battery and you want to use C-Gryphon™ either for serial configuration, software
upgrades or to hold Gryphon™ Mx30. Since this type of battery must not be charged
it is necessary to disable the C-Gryphon™ charge function by following the
procedure:
With the Gryphon™ Mx30 read the following code:
1.
The green LED on the Gryphon™ Mx30 will blink, signaling the reader has
accepted the command.
Place the reader onto the charger within 10 seconds. The green LED turns
2.
off and a short beep is emitted
To enable the charge function repeat step 1 and 2 substituting the "Alkaline" code
with the following one:
Attempts to charge Alkaline batteries could cause leakage of liquid,
generation of heat or, in extreme cases, explosion. If using Alkaline
batteries, carefully follow the procedure above to avoid damage.
CAUTION
Alkaline
Ì$+RN4$-]Î
NiMh/NiCd
Ì$+RN6$-gÎ