Datalogic PowerScan D8530 Family Quick Reference Manual
Datalogic PowerScan D8530 Family Quick Reference Manual

Datalogic PowerScan D8530 Family Quick Reference Manual

Hide thumbs Also See for PowerScan D8530 Family:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PowerScan D8530 Family

  • Page 2 Datalogic reserves the right to change any specification at any time without prior notice. Datalogic is a registered trademark of Datalogic S.p.A. in many countries and the Datalogic logo is a trademark of Datalogic S.p.A. all licensed to Datalogic Scanning, Inc. All other trademarks and trade names referred to herein are property of their respective owners.
  • Page 3: Table Of Contents

    CONTENTS Updates and Language Availability ..................iv ® PowerScan D8530 family Description ................1 Using PowerScan® D8530 family ..................2 Indicators ..........................3 Setup ..........................3 Connections ........................4 Interface Selection ......................7 Wedge Keyboard Nationality....................8 USB Keyboard Nationality....................9 Reading Parameters ......................10 Default Configuration ......................11 Operating Test ........................13 Technical Features......................14 Service and Support......................18 Warranty ...........................18...
  • Page 4: Updates And Language Availability

    UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.scanning.datalogic.com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana.
  • Page 5: Powerscan ® D8530 Family Description

    POWERSCAN® D8530 FAMILY ® POWERSCAN D8530 FAMILY DESCRIPTION The present manual includes just a few commands to allow the startup of the scanner and setting of the required interface. For complete configuration of the scanner, refer to the PowerScan D8530 Reference Manual or the Aladdin configuration program, both downloadable from the website and available on the included CD ROM.
  • Page 6: Using Powerscan® D8530 Family

    DATALOGIC USING POWERSCAN® D8530 FAMILY PowerScan® D8530 normally functions by capturing and decoding codes. The PowerScan® D8530 reader uses an intelligent aiming system. By pulling the trigger, the aiming system indicates a field of view, which should be positioned over the code: Aiming System When you pull the trigger, a red beam illuminates the code.
  • Page 7: Indicators

    POWERSCAN® D8530 FAMILY INDICATORS LED INDICATORS The PowerScan® D8530 family uses green LED indicators to signal the following reader functions: STATUS BEHAVIOR Power ON At power-on, the LEDs blink briefly, then light up for 2 seconds to signal the power supply is present.
  • Page 8: Connections

    DATALOGIC CONNECTIONS CONNECTING THE CABLE Rubber gasket Plastic boot Cable spacer Cover Strain relief Align Slip the cover over the cable. Push the plastic boot into the rubber gasket. Take care that the Notch tab on the plastic boot is aligned with the notch in the rubber gasket.
  • Page 9 POWERSCAN® D8530 FAMILY RS-232 WEDGE The USB interface is compatible with: ® ® Windows 98 (and later) IBM POS for Windows Mac OS 8.0 (and later) 4960 Operating System...
  • Page 10 DATALOGIC START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the PowerScan® D8530™. During this phase the green LED on the PowerScan® D8530™ reader blinks and normal operations are suspended. The correct USB driver must be loaded before the PowerScan...
  • Page 11: Interface Selection

    POWERSCAN® D8530 FAMILY INTERFACE SELECTION RS-232 WEDGE – IBM AT AMHKHMFOHNGNENEIEPANHOGOCK AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFEHFKK AGPEPJAMDKEOFMHMLJALFAEHKK AMGNPJCJGIIJCMCEGJMHNDOLLK AEONPJCJGIIJCMCEHPLLHLPPJK AIFBJLBGMHPLNKECPCGMBBIBOK AIFBJLBGMHPLNPDFHGDGFIBDOK AAPHBAJJDAAGMGKDDAOHBGGLHK AAPHBAJJCGCOPJDIMBCEANODDK AEKFBONJCDDIECLFJIJKMCHLIK AFKFBPPJPJCAALOIKIECIPIKLK DLDDLDLDLLDLLLLDLLDDDLDLLL DDLDLDLDDLDLLLLDDDDDDLDLDL USB BULK USB KB EMULATION AMHKHMFOHNGNENEIEPANHOGOCK AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFDDHKK AGPEPJAMDKEOFMHMLJAKEDBEKK AEGNPJCJGIIJCMCEHIJOCEMNPK AMGNPJCJGIIJCMCFHMNJLBJPHK AIFBJLBGMHPKMICPIAFFEONCOK AIFBJLBGMHPKNMBGMJOJEHHAOK AAPHBAJJCCDBHCPKNDBPGLDBBK AAPHBAJICDHCJBCNKPCNNJNFHK AHLFBOPHCJGEMAMPAAEOMGMJKK AFLFBMPJIKPAMFFBBHKCCKNIKK DDDDLDLDLLDLLLLDDDLDDLDLLL DLLDLDLDLLDLLLLDDDDDDLDLLL...
  • Page 12: Wedge Keyboard Nationality

    DATALOGIC WEDGE KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not through the Restore Default code. Select one of the following keyboard nationality codes. Belgian English AMHKHNFMFNGNENEIEPANHOGOCK AMHKHNFMFNGNENEIEPANHOGOCK AGOEPBIMDKEOFMHMLJAKFHHHKK AGPEPBIMDKEOFMHMLJAKFGDHKK AMONPJCJGIIJCMCEHIOEHOELLK AMGNPJCJGIIJCMCEGIPKHKFBFK AIFBJLBGMHPLMLDIEKHJAIJDOK AIFBJLBGMHPLNMDJCBLKLEHAOK...
  • Page 13: Usb Keyboard Nationality

    POWERSCAN® D8530 FAMILY USB KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not through the Restore Default code. Select one of the following keyboard nationality codes. Belgian English AMHKHNEIHNGNENEIEPANHOGOCK AMHKHNEIHNGNENEIEPANHOGOCK AGOEPBIMDKEOFMHMLJAKEGBGKK AGPEPBIMDKEOFMHMLJAKEHFGKK AMONPJCJGIIJCMCFHMKLPKLHPK AMGNPJCJGIIJCMCFGMLFPOKNBK AIFBJLBGMHPLNMCPOFAOBCPDOK AIFBJLBGMHPLMLCOIOMNKOBAOK AAPHBAJIDCAHEOLPFCIKHIOFFK...
  • Page 14: Reading Parameters

    DATALOGIC READING PARAMETERS GOOD READ SPOT DURATION ♦ Short Disabled AMHKHNGMFNGNENEIEPANHOGOCK AMHKHNGMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJAKEEGEKK AGPEPBIMDKEOFMHMLJALEAFGKK AMGNPJCJGIIJCMCEHMNEPKCDPK AEONPJCJGIIJCMCEGKKIFCDHNK AIFBJLBGMHPLNKHNAEHPNLGDOK AIFBJLBGMHPLNPAKIACFJCPBOK AAPHBAJIDFDNGNPJFBDBHFOHHK AAPHBAJICDBFFCGCKAPCGOGPDK AHLFBOIEEHIOMFIGJFGGIFJKKK AGLFBPKEJNJGIMNLKFLOMIGLJK DDDDLDLDDDLLLLLDDLDDDLDLLL DLLDLDLDLDLLLLLDLDDDDLDLDL Medium Long AMHKHNGMFNGNENEIEPANHOGOCK AMHKHNGMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJAKEDCGKK AGPEPBIMDKEOFMHMLJALFAHFKK AEGNPJCJGIIJCMCEGNINANAFLK AMONPJCJGIIJCMCFGOOPMHGFFK AIFBJLBGMHPKMIBAHGEGIEDAOK AIFBJLBGMHPLMLDDMJJJJLFDOK AAPHBAJICHAKNJKALCMJAILNBK AAPHBAJJCCFGLBLFNMMANMILFK AEKFBOKKENNCEHPMANLCIBCIIK AELFBNKKDOACIJEFLCFCCEHKJK DLDDLDLDDDLLLLLDLDLDDLDLLL DDDDLDLDLDLLLLLDLDLDDLDLDL...
  • Page 15: Default Configuration

    POWERSCAN® D8530 FAMILY DEFAULT CONFIGURATION RS-232 Standard DEFAULT SETTINGS 115200 baud, no parity, 8 data bits, 1 stop bit, no handshake, no protocol, FIFO enabled, intercharacter delay = 0, intercode delay = 0, serial trigger lock disabled, serial trigger lock disable character = NUL, serial trigger lock enable character = NUL, RX Timeout = 10 sec USB COM Emulation DEFAULT SETTINGS...
  • Page 16 DATALOGIC CODE SELECTION issue identical codes = enable enabled codes Standard Code 39: no check digit control, variable code length; EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled Interleaved 2/5: check digit control and transmission, variable code length...
  • Page 17: Operating Test

    POWERSCAN® D8530 FAMILY OPERATING TEST EAN-13 Code 39 (Standard) 1 234567 000992 Code 128 PDF417 Data Matrix (Normal)
  • Page 18: Technical Features

    DATALOGIC TECHNICAL FEATURES PowerScan® D8530 Family Common Features Electrical Features Operating Voltage 5 to 30 V Power Consumption @ 5V (Typical) 600 mA @30V (Typical) 100 mA Communications Features Standard Interfaces RS-232, Keyboard emulation AT IBM, USB COM emulation, USB Keyboard emulation...
  • Page 19 POWERSCAN® D8530 FAMILY PowerScan® D8530™ Optical Features Focus distance 140 mm Field of view 28° (H) x 23° (V) Horizontal field of view at 0.52d + 15 distance (d) in mm Vertical field of view at 0.42d + 12 distance (d) in mm Max Resolution Linear codes - PDF 417 –...
  • Page 20 DATALOGIC PowerScan® D8530™ HD Optical Features Focus distance 65 mm Field of view 27° (H) x 22° (V) Horizontal field of view at 0.50d + 13 distance (d) in mm Vertical field of view at 0.40d + 10 distance (d) in mm...
  • Page 21 POWERSCAN® D8530 FAMILY PowerScan® D8530™ WA Optical Features Focus distance 115 mm Field of view 54° (H) x 45° (V) Horizontal field of view at 1.04d + 40 distance (d) in mm Vertical field of view at 0.40d + 10 distance (d) in mm Max Resolution Linear codes -...
  • Page 22: Service And Support

    3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term.
  • Page 23: Compliance

    FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
  • Page 24: Laser Safety

    DATALOGIC LASER SAFETY The PowerScan® D8530 hand-held reader is a Class 1 LED product regarding its Illuminator and a Class 2 laser product regarding its Aiming System. LED Illuminator The use of an illuminator in the PowerScan® D8530 hand-held reader is a...
  • Page 25 POWERSCAN® D8530 FAMILY ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture.
  • Page 26 DATALOGIC DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit.
  • Page 27: Power Supply

    POWERSCAN® D8530 FAMILY ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1.
  • Page 28: Weee Compliance

    Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
  • Page 29 POWERSCAN® D8530 FAMILY NOTES...
  • Page 30 DATALOGIC NOTES...
  • Page 31: Declaration Of Conformity

    EC-049 DECLARATION OF CONFORMITY REV.: 0 Pag.: 1 di 1 Datalogic Scanning Group Srl Via S. Vitalino, 13 Lippo di Calderara di Reno (BO) 40012 Italy dichiara che declares that the déclare que le bescheinigt ,daß das Gerät declare que el POWERSCAN D8530 ;...