5
Read one number in the range 1 to 5 to divide the code into fields.
6
Each code field length can be set by either:
a) defining a field separator character to be found in the code itself. In this case you can
choose to discard the code separator character or include it as the last character of the
field.
b) defining a match character to be found consecutively repeated in the code itself. In this
case the field ends with the first character that does not match.
c) specifying a specific character length up to the maximum of 99 characters.
d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will
not be transmitted.
ADVANCED FORMATTING
Divide Code into Fields
divide code into fields
ÌHF.Î
Define Code Fields
define code fields
OR BY
OR BY
OR BY
Exit and Save Configuration
Ì$-?Î