Warnings

The following warnings are for the setup, use, maintenance, and repair of this equipment. The exclamation point
symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these sym-
bols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard
symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
FIRE AND EXPLOSION HAZARD (GROUNDING)
Some oil-based and flammable materials generate static electricity when sprayed. Static electricity creates
an explosion and fire risk. Your sprayer has a grounding cord that will conduct the static electricity to a
grounded electrical outlet. The sprayer and all objects in spray area shall be properly grounded to protect
against static discharge, sparks or shocks.
Connect the grounding cord when spraying flammable or static producing oil-based materials.
If there is static sparking or if you feel a shock, stop spraying immediately and connect the sprayer to a
properly grounded electrical outlet with the ground wire provided.

GROUNDING INSTRUCTIONS

Move the sprayer away
from the spray area to
a non-hazardous
location. Plug the
ground wire
into the sprayer.

Grounding Wire Repair

If the grounding wire breaks at the spool end,
perform the following steps:
1. Unwind wire from grounding spool and use a flat
screwdriver to pry apart the grounding spool.
2. Loosen screw on terminal and remove broken wire.
Strip insulation from grounding wire, insert into ter-
minal and tighten screw.
3A1698G
WARNING
WARNING
WARNING
WARNING
ti17082a
ti17080a
Unwind the ground wire from the spool
and plug it into a properly grounded
electrical outlet.
If the ground wire is not long enough to
reach a grounded electrical outlet, a
3-wire grounded extension cord may be
used to reach a grounded outlet.
3. Snap the grounding spool back together.
If the grounding wire breaks at the grounding plug,
perform the following steps:
1. Pull rubber boot off of wire at grounding plug and
slide boot over grounding wire.
2. Loosen screw and remove broken wire. Insert
stripped grounding wire and tighten screw.
3. Replace rubber boot onto grounding plug.
Warnings