The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment.
The exclamation point symbol alerts you to a general warning and the hazard symbols refer to
procedure-specific risks. When these symbols appear in the body of this manual or on warning labels,
refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section
may appear throughout the body of this manual where applicable.
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces
the risk of electric shock by providing an escape wire for the electric current. This product is
equipped with a cord having a grounding wire with an appropriate grounding plug. The plug
must be plugged into an outlet that is properly installed and grounded in accordance with all
local codes and regulations.
Improper installation of the grounding plug is able to result in a risk of electric shock.
When repair or replacement of the cord or plug is required, do not connect the grounding
wire to either power terminal.
The wire with insulation having an outer surface that is green with or without yellow
stripes is the grounding wire.
Check with a qualified electrician or serviceman when the grounding instructions are not
completely understood, or when in doubt as to whether the product is properly
grounded.
Do not modify the plug provided. If it does not fit the outlet, have the proper outlet
installed by a qualified electrician.
This product is for use on a nominal 120 V or 230 V circuit and has a grounding plug
similar to the plugs illustrated in the figure below.
Only connect the product to an outlet having the same configuration as the plug.
Do not use a 3-to-2 adapter with this product.
Extension Cords:
Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle
that accepts the plug on the product.
Make sure your extension cord is not damaged.
If an extension cord is necessary, use 12 AWG (2.5 mm
that the product draws.
An undersized cord results in a drop in line voltage and loss of power and overheating.
3A9095C
230 V
120 V
230 V
230 V
ANZ
India
2
Warnings
110 V UK
) minimum to carry the current
5