Shutdown and Cleaning

Failure to properly clean sprayer after each use will
result in hardened materials, damage to the sprayer, and
the warranty will no longer be valid. Do not store solvents
other than mineral spirits in sprayer. Always flush with
Graco pump armor prior to storage.

Flushing Sprayer

Do not spray solvents through the spray tip. Clean the tip
in a bucket of compatible solvent.
Keep spray area well-ventilated. Keep a good supply of
fresh air moving through the area.
Protect the internal parts of this sprayer from water.
Do not submerge the sprayer in cleaning fluid. Openings
in shroud allow cooling of mechanical parts and electron-
ics inside. If water or cleaning fluid gets into these open-
ings, the sprayer could malfunction or become
permanently damaged.
1. Engage trigger lock and pull prime/pressure relief
valve UP to release pressure.
ti16699a
i14994
2. Remove material cup and return excess material to
proper container. If used, properly dispose the cup
liner.
ti15000a
3A1698G
NOTICE
NOTICE
ti16700a
ti16724a
3. Remove and clean sprayer intake tube and screen
with water (or flushing fluid) and a brush every time
you flush the sprayer. Reconnect intake tube.
ti15002a
4. Clean cup if not using a liner, and fill with water or
appropriate flushing fluid.
ti16726a
ti15001a
5. Reconnect material cup and shake sprayer to move
clean water around and clean all areas inside of
cup.
6. Disconnect trigger lock and trigger sprayer for
approximately 15 seconds. Engage trigger lock.
ti16993a
7. Discard contaminated fluid and refill with appropri-
ate flushing fluid.
Shutdown and Cleaning
ti16725a
ti15441a
ti16723a
ti16716a