1.4 COMPONENT CHECK LIST
Within the Electromax Solar packaging the following components are supplied. Please check
that all parts are available before commencing installation.
• Electromax Solar
• Cold water combination valve
• Programmable room thermostat
• Immersion heater key spanner
• Hose connection adaptor for primary system drain valve
• Set of cable entry glands and blanking plugs (5 x 20mm, 1 x 25.4mm)
• Installation manual
• User instructions
• Fitting template
Warranty card
Divertor valve ( East/West models only )
2.0 TECHNICAL SPECIFICATIONS
2.1 GENERAL
Capacity (Total)
Capacity (Solar)
Weight (Empty)
Weight (Full)
Height
Width
Depth
2.2 DHW CYLINDER
Rated pressure
Operating pressure
Supply pressure
Temp' & pressure relief valve
Pressure reducing valve
Expansion relief valve
Expansion vessel capacity
Expansion vessel pre charge
Check Valve
Strainer
Coil heat exchanger
Lower immersion heater
Upper immersion heater
Thermostatic control
Over temperature Control
185 litre
220 litre
65 litre
75 litre
94kg
105.5kg
279kg
325.5kg
1580mm
1800mm
550mm
550mm
600mm
600mm
0.6 MPa (6 bar)
0.35 MPa (3.5bar)
0.15 MPa min (1.5bar) – 1.6 MPa max (16bar) max at
PRV
1.0 MPa (10bar) / 90ºC
0.35 MPa (3.5bar)
0.6 MPa (6bar) Fitted in Cold Water Combination Valve
18 litre
0.35 MPa (3.5bar)
Fitted in Cold Water Combination Valve
Fitted in Cold Water Combination Valve
Stainless Steel tube, Ø25mm, 1.1m² surface area
3kW 825 alloy sheathed element (curved)
3kW 825 alloy sheathed element (straight)
10 – 70°C rod type thermostats
85ºC manually re-settable double pole cut out
250 litre
80 litre
112kg
362kg
1990mm
550mm
600mm
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents