4.8.6 PROGRAMMING MENU
The programming menu is used to the check parameters which may be changed.
FIGURE 31: PROGRAMMING MENU ICONS
INDICATION
01°C max.
dT max 7 K
dT min 3 K
min 100
2
To check / alter a parameter:
Select the programming sub menu as shown in section 4.8.4
Press UP or DOWN to scroll to the required parameter.
Press RIGHT to select the parameter. The icon will flash.
Press UP to increase the parameter value.
Press DOWN to decrease the parameter value.
Press RIGHT and the OK icon will flash.
Press RIGHT to confirm the parameter setting.
4.8.7 MANUAL OPERATION MENU
The manual operation menu allows the solar sytem to be operated by hand for test / service
purposes.
NOTE: During manual operation there is no auotmatic regulation of the system.
FIGURE 32: MANUAL OPERATION MENU ICONS
INDICATION
To manually operate the solar pump:
Select the manual operation sub menu as shown in section 4.8.4
Press UP or DOWN to switch the pump ON or OFF.
Press RIGHT to confirm the setting.
NOTE: Automatic regulation will be re actived after 8 hours.
46
DESCRIPTION
MAXIMUM STORAGE TANK
TEMPERATURE
STORAGE TANK SWITCH ON
DIFFERENCE (dTon)
STORAGE TANK SWITCH OFF
DIFFERENCE (dTo )
PUMP SPEED CONTROL
(100% = SPEED CONTORL OFF )
DESCRIPTION
SWITCH SOLAR CIRCULATION PUMP ON / OFF
FACTORY SET
RANGE
65°C
15 - 95°C
7K
3 - 40 K
2 - 25 K
3K
100%
30 - 100%
RANGE
1 = ON
0 = OFF

Hide quick links: