Heatrae Sadia ELECTROMAX SOLAR Installation & Servicing Instructions Manual page 10

Table of Contents

Advertisement

2.3 SOLAR CONTROLLER & SOLAR PRIMARY CIRCUIT
Rated pressure
Operating pressure
Pressure relief valve
Expansion vessel capacity
Expansion vessel pre charge
Flow meter
Air vent
Check valves
Circulating pump
Heat transfer fluid
Thermostatic control
Over temperature control
2.4 ELECTRIC BOILER & CENTRAL HEATING PRIMARY CIRCUIT
Rated pressure
Operating pressure
Pressure relief valve
Expansion vessel capacity
Expansion vessel pre charge
Automatic bypass valve
Automatic air vent
Circulating pump
Electric boiler
Thermostatic Control
Over temperature Control
2.5 CYLINDER PERFORMANCE
TABEL 01:
MODEL
AUXILIARY
VOLUME
185
220
250
Heat up time is based on raising the auxillary volume from 15ºC to 60ºC using the lower 3kW
immersion heater.
Boost Volume = 57 Litres
Heating times using solar primary circuit will be variable as they will depend on the amount of
solar radiation, sunshine hours, collector panel type, size and orientation.
10
1.0 MPa (10bar)
0.2 – 0.4 MPa (2 - 4bar)
0.6 MPa (6 bar)
24 litres (supplied separately)
0.35 MPa ( 3.5bar) (supplied separately)
2 – 15 litre/min
Manual type, fitted
x2 fitted
Grundfos UPS 15-50
Glycol / Water 40/60 mix (supplied separately)
Electronic controller
85ºC manually re-settable double pole cut out
0.3 MPa (3bar)
0.1 MPa (1bar)
0.3 MPa (3bar)
12 litres
0.1 MPa (1bar)
`
0.05 MPa (0.5bar)
Fitted
Grundfos UPS 15-50
9kW Electric flow type
Electronic Controller: Radiator 65 ºC - 80 ºC
85ºC manually resettable double pole cut out
HEAT UP TIME
- AUX (MINS)
120
126
145
152
170
178
Underfloor 30 ºC - 60 ºC
HEAT UP TIME -
BOOST (MINS)
60
60
60
STANDING HEATLOSS
kWhr/24hr
1.76
1.73
1.70