Overview; Applications And Installation - KMC Controls FlexStat Operation Manual

Bacnet programmable thermostats
Hide thumbs Also See for FlexStat:
Table of Contents

Advertisement

Overview

The award-winning KMC FlexStat series of intelli-
gent temperature/humidity/occupancy-sensing, wall-
mounted, thermostat/controllers are native BACnet
Advanced Application Controllers (B-AAC) for use
in a BACnet system. The FlexStat simplifies net-
worked zone control for common packaged HVAC
equipment, such as packaged rooftop units, fan coil
units, heat pumps, and other similar applications. In
addition, applications such as pressure dependent
VAV, terminal reheat, and medium-sized central
station air handling equipment applications may
also be addressed through the on-board libraries of
programs built into the devices.
The on-board library of programs permits rapid
configuration of a wide range of HVAC control ap-
plications.
The FlexStat series also provides the capability to
customize the standard library of sequences using
KMC's BACstage programming tool. This enables a
local authorized KMC installing contractor to adapt
the standard library to the unique site needs and ap-
plication specific requirements of a particular project.
Dimensions in
inches (mm)
5.551
(141)
1.125
(28.6)
EIA-485 Data Port for
Quick Network Access
FlexStat

Applications and Installation

Communication with
Other BACnet Devices
Temperature
24 Volts AC
Power
1. Wire the FlexStat's backplate to the desired
equipment and set the FlexStat's end-of-line and
input pull-up resistor switches.
2. Select the relevant application and options from
the (Advanced) Application submenu of the
Advanced Menu and other appropriate menus.
3. Configure the FlexStat for the BACnet network.
Terminal Blocks
(See Network Connection on page
on Removable
Backplate for
For general mounting and connection details,
Easy Wiring
including network wiring, EOL termination, power
connections, input/output connections, pull-up
resistor switch settings, see the relevant model's
Installation Guide. For extended information about
wiring and sequences for specific applications, see
the FlexStat Application Guide.
CAUTION
To avoid damage from ground loops and other
communication issues in networked FlexStats,
correct phasing on network and power
connections on ALL the networked controllers
is critically important.
3
Optional
Humidity
Sensing
3 Analog
Inputs
Outputs
for Other
Sensors or
Contacts
Quick (Temporary) Network/
and
Applications
Motion
• AHU
Sensing
• FCU
• HPU
• RTU
Up to 9
(Analog
and/or
Relays)
Programming Access
18.)
Operation Guide, Rev. K