Leg Leveling Note:
This appliance is equipped with
four leveling bolts that can be
adjusted by tipping the firebox
and unscrewing them from the
base.
Also note that use of the
leveling bolts will affect
required minimum clearance to
combustible top trim and mantle
construction. See the figures and
tables on pages 8 and 9.
23 ⁄ "
Gas Inlet
597
mm
C L
8 ⁄ "
222
mm
16 ⁄ "
416
mm
Figure 2. Firebox dimensions.

Installation

Requirements
This insert can be installed in most solid fuel burning
fireplaces of either masonry construction or a
prefabricated factory built fireplace.
Prior to any installation, the existing chimney flue
must be thoroughly cleaned and inspected by a qualified
chimney sweep or fireplace service person.
Do not install this appliance into a chimney that is
damaged or contains combustible construction materials.
Any repairs must be made prior to installing the insert.
The chimney and fireplace must be in good working order.
Chimney cleanouts must be accessible and fit properly.
If you are unsure of the condition of your fireplace and
chimney, contact a professional fireplace technician
or your local authorized Jøtul dealer for professional
assistance.
14 ⁄ "
365
mm
23 ⁄ "
600
mm
2"
51
mm
23 ⁄ "
594
mm
2 ⁄ "
70
mm
33 ⁄ "
845
mm
Cast Iron Overlay
Glass Viewing Area
27 ⁄ " x 19 ⁄ "
705
x 495
mm
mm
34 ⁄ "
883
mm
DO NOT REMOVE BRICKS OR MORTAR FROM THE
FIREPLACE OR CHIMNEY STRUCTURE. However, masonry
or steel may be removed from the smoke shelf and
adjacent damper frame area to accommodate installation
of a chimney liner, provided that their removal will not
weaken the structure of the fireplace or chimney, and will
not reduce protection for combustible materials.
If the fireplace has been modified to accommodate
installation, use anchors or masonry nails to attach the
metal Fireplace Conversion Notice Plate to the back wall
of the masonry fireplace firebox where it will be readily
seen should the insert be removed.
THIS APPLIANCE MUST NOT BE CONNECTED TO A
CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE
OF ANY KIND. All venting components must be
installed in accordance with the terms of their listing
and manufacturer's instructions. Refer to the pipe
manufacturer's instructions for proper pipe clearances.
139712_R00 GI 635 IPI Sept. 2015