Figure 14. Fuel Conversion Components.
Pilot Assembly
Front Burner Air
Shutter Cable
Pilot Head
Flame
Sensor
Pilot Orifice Lever
Figure 15. Pilot Conversion to Propane.
8. CHANGE THE VARIABLE REGULATOR TOWER on the gas
control valve. See fig. 16.
• Remove the heat shield from the valve compartment
to access the Regulator Tower.
• Disconnect the IFC lead from the regulator lead.
• Remove the original regulator tower with removal of
two Torx mounting screws.
* Install the new regulator tower from the kit using the
screws previously removed. Tighten screws securely.
Reconnect the Regulator lead to the IFC lead.
9. Apply the conversion notice labels included in the kit to
the appliance where they will be visible to any person
who may be servicing the unit.
• Label "A": Apply to the right side compartment adjacent to
the Rating Plate.
• Label "B": Apply to the Rating Plate.
• Small valve sticker: Apply to valve body.
10. Use an electronic gas detector or soap solution to test
for leaks at the pilot head and all gas line joints.
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.
11. Pressure Test: Conduct a pressure test of the valve
following the guidelines on page 14 of this manual.
12. Burner Confirmation: Follow Steps 1 -5 under Initial
System Check on page 30 before final assembly of
accessory, log set, and surround components.
Front Burner
Injector
Air Shutter
Adjustor Trays
Ignitor
Rear Burner
Injector
Regulator
Lead to IFC
Lead
Regulator
Tower
Front Burner Air
Shutter Cable
Figure 16. Replace the Regulator Tower.
139712_R00 GI 635 IPI Sept. 2015
Rear Burner Air
Shutter Cable
Remove
Heat Shield