Remote Condenser/Line Set Installation; Remote Ice Machines Refrigerant Charge - Manitowoc S Use And Care Manual

Manitowoc inc installation use and care manual ice machines s
Hide thumbs Also See for S:
Table of Contents

Advertisement

Section 2

Remote Condenser/Line Set Installation

Remote Single
Ice Machine
Condenser
S500
S600/S800/S1000
S1400/S1600/
S1800
*Line Set
Discharge Line
RT
1/2" (1.27 cm)
RL
1/2" (1.27 cm)
Air Temperature Around the Condenser
Minimum
-20°F (-29°C)
REMOTE ICE MACHINES
REFRIGERANT CHARGE
Each remote ice machine ships from the factory with a
refrigerant charge appropriate for installation with line
sets of up to 50' (15.25 m). The serial tag on the ice
machine indicates the refrigerant charge.
Additional refrigerant may be required for installations
using line sets between 50' and 100' (15.25-30.5 m)
long. If additional refrigerant is required, refer to the
chart below for the correct amount to be added.
Ice Machine
S500
S600
S850
S1000
S1400
S1600
S1800
Part Number 80-1620-3
Circuit
Line Set*
RT-20-R404A
JC0495
RT-35-R404A
RT-50-R404A
RT-20-R404A
JC0895
RT-35-R404A
RT-50-R404A
RL-20-R404A
JC1395
RL-35-R404A
RL-50-R404A
Liquid Line
5/16" (.79 cm)
3/8" (.95 cm)
Maximum
120°F (49°C)
Nameplate Charge
(Charge Shipped in Ice Machine)
6 lb. (96 oz.)
6.5 lb.(104 oz)
8.5 lb. (136 oz.)
8.5 lb. (136 oz.)
11 lb. (176 oz.)
Not Available at Time of Printing, Please Refer to Nameplate on Ice Machine
12.5 lb. (200 oz.)
IMPORTANT
EPA CERTIFIED TECHNICIANS
If remote line set length is between 50' and 100' (15.25-
additional
30.5 m), add
Refer to the Installation Instructions in Installation Use and
Care Manual for the model being worked on.
Tubing length: ______________________________
Refrigerant added to nameplate: ________________
New total refrigerant charge: ___________________
Typical Additional Refrigerant Label
Potential Personal Injury Situation
The
ice
machine
Installation of the line sets must be performed by a
properly trained and EPA certified refrigeration
technician aware of the dangers of dealing with
refrigerant charged equipment.
Never add more than nameplate charge to the
refrigeration system for any application.
Refrigerant to be Added for
50'-100' Line Sets
1.5 lb. (24 oz.)
1.5 lb. (24 oz.)
2 lb. (32 oz.)
2 lb. (32 oz.)
2 lb. (32 oz.)
2 lb. (32 oz.)
Installation Instructions
refrigerant to the nameplate charge.
Warning
!
contains
refrigerant
! Caution
Maximum System Charge
(Never Exceed)
7.5 lb. (120 oz.)
8 lb. (128 oz.)
10.5 lb. (168 oz.)
10.5 lb. (168 oz.)
14 lb. (224 oz.)
14.5 lb. (232 oz.)
charge.