Non-Manitowoc Multi-Circuit Condenser Sizing Chart - Manitowoc S Use And Care Manual

Manitowoc inc installation use and care manual ice machines s
Hide thumbs Also See for S:
Table of Contents

Advertisement

Installation Instructions

NON-MANITOWOC MULTI-CIRCUIT CONDENSER SIZING CHART

Refrigerant
Ice
Machine
Model
Type
Charge
S500
R-404A
6 lbs.
S600
R404A
6.5 lbs.
S850
R-404A
8.5 lbs.
S1000
R-404A
8.5 lbs.
S1400
R-404A
11 lbs.
S1600
R-404A
S1800
R-404A
12.5 lbs.
SINGLE CIRCUIT REMOTE
CONDENSER
ELECTRICAL
DISCONNECT
ELECTRICAL
SUPPLY
2-20
Heat of Rejection
Volume (cu ft)
Average
Peak
Btu/hr
Btu/hr
7,000
9,600
0.020
9,000
13,900
0.045
12,000
18,000
0.045
16,000
22,000
0.045
19,000
28,000
0.085
Not Available at Time of Printing
24,000
36,000
0.085
DISCHARGE
LINE
LIQUID LINE
BIN
DISCHARGE
REFRIGERANT
LINE
Typical Single Circuit Remote Condenser Installation
Internal
Condenser
Design
Pressure
Min
Max
500 psig
(3447 kpa)
0.035
(34.47 bar)
safe working
pressure
0.060
0.060
2,500 psig
(17237 kpa)
0.060
(172.37 bar)
0.105
burst
pressure
0.105
ICE MACHINE
LIQUID
REFRIGERANT
LINE
Quick Connect Stubs-
Male Ends
Discharge
Liquid
coupling
coupling
P/N
P/N
83-6035-3
83-6034-3
mounting
mounting
flange P/N
flange P/N
83-6006-3
83-6005-3
ELECTRICAL
DISCONNECT
TO CIRCUIT
BREAKER
PANEL
36.00"
(91.44 cm)
DROP
SV1615
Part Number 80-1620-3
Section 2
Head
Pressure
Control
Valve
Manitowoc
P/N
83-6809-3
no