Remote Condenser/Line Set Installation; Remote Ice Machines Refrigerant Charge - Manitowoc QD0322A Use And Care Manual

Q model ice machines
Hide thumbs Also See for QD0322A:
Table of Contents

Advertisement

Section 2

Remote Condenser/Line Set Installation

Remote Single
Ice Machine
Condenser
Q490
Q690
Q890
Q1090
Q1390
Q1690
Q1890
*Line Set
Discharge Line
RT
1/2" (12.7 mm)
RL
1/2" (12.7 mm)
Air Temperature Around the Condenser
Minimum
-20°F (-28.9°C)
REMOTE ICE MACHINES
REFRIGERANT CHARGE
Each remote ice machine ships from the factory with a
refrigerant charge appropriate for installation with line
sets of up to 50' (15.25 m). The serial tag on the ice
machine indicates the refrigerant charge.
Ice Machine
Q490
Q690
Q890
Q1090
Q1390
Q1690
Q1890
Part No. 80-1375-3
Circuit
Line Set*
JC0495
RT-20-R404A
JC0895
RT-35-R404A
RT-50-R404A
JC1095
JC1395
RL-20-R404A
JC1695
RL-35-R404A
JC1895
RL-50-R404A
Liquid Line
5/16" (7.9 mm)
3/8" (9.5 mm)
Maximum
120°F (49°C)
Nameplate Charge
(Charge Shipped in Ice Machine)
6 lb. (96 oz.)
8 lb. (128 oz.)
8 lb. (128 oz.)
9.5 lb. (152 oz.)
12.5 lb. (200 oz.)
15 lb. (240 oz.)
15 lb. (240 oz.)
Additional refrigerant may be required for installations
using line sets between 50' and 100' (15.25-30.5 m)
long. If additional refrigerant is required, an additional
label located next to the Model/Serial Numbers decal
states the amount of refrigerant to be added.
IMPORTANT
EPA CERTIFIED TECHNICIANS
If remote line set length is between 50' and 100' (15.25-
1.5 lb. (24 oz) (0.68 kg)
30.5 m), add
nameplate charge.
Tubing length: _______________________________
Refrigerant added to nameplate: ________________
New total refrigerant charge: ___________________
Typical Additional Refrigerant Label
If there is no additional label, the nameplate charge is
sufficient for line sets up to 100' (30.5 m). (See the chart
below.)
Potential Personal Injury Situation
The ice machine contains refrigerant charge. Installation
of the line sets must be performed by a properly trained and
EPA certified refrigeration technician aware of the dangers
of dealing with refrigerant charged equipment.
Refrigerant to be Added for
50'-100' Line Sets
None
None
None
None
1.5 lb. (24 oz)
2.0 lb. (32 oz)
2.0 lb. (32 oz)
Installation Instructions
of refrigerant to the
WARNING
Maximum System Charge
(Never Exceed)
6 lb. (96 oz.)
8 lb. (128 oz.)
8 lb. (128 oz.)
9.5 lb. (152 oz.)
14 lb. (224 oz.)
17 lb. (272 oz.)
17 lb. (272 oz.)
2-13

Hide quick links:

Advertisement

Table of Contents
loading