Maintenance
3. Water Distribution Tube
Removing the distribution tube while the water
pump is running will allow water to spray from ice
machine. Disconnect the electrical power to the ice
machine and dispenser at the electric service switch
box and turn off the water supply.
NOTE: Distribution tube thumbscrews are retained by o-
rings to prevent loss. Loosen thumbscrews but do not
pull thumbscrews out of distribution tube.
B
Water Distribution Tube Removal
A. Remove outer half of distribution tube by
loosening the four (4) thumbscrews (o-rings
retain thumbscrews to distribution tube).
B. Pull inner half of water distribution tube forward
to release slip joint from water pump tubing
connection.
4-8
Warning
!
A
4. Water Trough
A. Depress tabs on right and left side of the water
trough.
B. Allow front of water trough to drop as you pull
forward to disengage the rear pins.
DEPRESS TABS