Horizontal Telescopic Top Flue Installation - Saunier Duval Themaclassic F30E Instructions For Use Installation And Servicing

Table of Contents

Advertisement

11 Horizontal Telescopic Top Flue Installation

The Horizontal Telescopic Top Flue, Kit No.
A2004500 is suitable for installations that
require a flue length from 425 minimum to
659.5 maximum. If longer flueing is required
extensions and bends are available, see note
below.
Note: Additional 1 metre extentions, 90° and 45° bends are
available. The maximum extended flue is 3.5m. The use of flue
bends requires the flue lengths to be reduced by 1m. for 90° and
0.5m. for 45°.
11.1 Horizontal Telescopic Top Flue kit of
parts, refer to diagram 11.1.
11.2 Installation of telescopic flue assembly
• Carefully pull to remove the elbow (D) from the air duct pipe
and flue duct pipe (A).
• Fit rubber sealing collar (E), see diagram 11.2, into groove at
the outer end of the air duct pipe (A).
• Fit air/flue duct pipe assembly, into wall from the outside with
rubber sealing collar to the outside.
• Pull pipe assembly inwards to bring rubber sealing collar hard
up against external wall.
• If the telescopic flue is pulled apart care must be taken not to
damage the 'O' ring on the flue duct when re-assembling.
• Remove the backing from the self adhesive gasket (F) and
carefully fit gasket to base of flue elbow.
• Fit the restrictor (a) inside the fan outlet, see diagram 11.3.
• Fit elbow onto boiler and secure with the four screws (G).
• Re-fit the telescopic flue duct pipe to the flue elbow . Secure
with the fixing collar (C) and fixing collar seal (B).
Horizontal telescopic flue system (rear and side)
The maximum permissible length (L) for the telescopic flue system is 659.5mm. The restrictor (a) must be fitted to
inside the fan outlet.
FLUE
RESTRICTOR
a
The flue kit A2004500 is 659.5 mm long and comprises:
- Telescopic flue assembly ..................................... A
- Fixing collar seal ..................................................... B
- Fixing collar ............................................................. C
- Elbow ....................................................................... D
- External rubber sealing collar ............................... E
- Gasket ...................................................................... F
- Screws ..................................................................... G
Telescopic Top flue kit
Gasket
21
A
B
D
F
MINIMUM
WALL
THICKNESS
193mm.
C
G
E
Diagram 11.1
Diagram 11.2
Diagram 11.3
4000122704-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Themaclassic f30e sb

Table of Contents