1 - ON/OFF switch
2 - Central heating
temperature selector
3 - Domestic hot water
temperature selector
(F30E Only)
4 - Pressure gauge (bar)
and temperature gauge (°C)
5 - Running lamp
illuminated green when
boiler is ON
(fault indicated by a red
flashing light)
6 - Programmer
(F30E Only, optional for
F30E SB)
1. Lighting the boiler :
Make sure that:
• The boiler is connected to the electrical supply.
• The gas service cock is open.
Switch ON ( I )
The running lamp will
illuminate green
2. Stop the boiler :
• Switch to OFF ( 0 ) the electrical
supply is OFF.
• Turn the gas supply OFF at the
gas service cock if the boiler is to
be out of use for a long time.
3. Domestic hot water adjustment
(F30E Only):
• Position ( 0 ): Domestic hot water OFF
• Position ( I ) and ECO: Domestic hot water
between approx. 38˚C and 55˚C
• ECO: Maximum recommended for
constant use
• Between ECO and MAX:
Occasional use for water above
approx. 55˚C
4. Heating temperature adjustment :
• Winter: Set the control knob
between 1 and 5
• Summer: Set the control knob
to
Controls and Lighting
3
4
2
5. If a fault occurs (indicated by red flashing
light) :
• Reset boiler: Switch On/Off switch to ( 0 ), wait for
five seconds. Turn the On/Off switch to ( I ) the
boiler is reset. If the fault continues call your
Installation/Servicing company or Heatcall.
(Saunier Duval's own service organisation) using
the telephone number on the front
cover of this literature.
6. Installation filling (F30E Only):
• If the boiler loses water: the pressure gauge (a)
and fault display (b) will flash. Fill the system by the
filling device (c) at the bottom of the boiler until the
pressure gauge reads 1.5 bar.
6. Installation filling (F30E SB Only):
• If the boiler loses water: the pressure gauge (a)
and fault display (b) will flash. Fill the system until
the pressure gauge reads 1.5 bar.
(a)
(b)
• Warning: Take care not to overfill the boiler . At a
pressure of 2.5 bar or above indicating over
pressure, the fault display (b) will flash. The
pressure must be reduced to 1.5 bar by bleeding a
radiator. If the fault continues call your Installation/
Servicing company or Heatcall. (Saunier Duval's
own service organisation) using the telephone
number on the front cover of this literature.
5
5
1
6
Diagram 1
(c)
Diagram 2
4000122704-1