Fixture Temperature (Temp); Fan Control (Fans); Adjustments And Calibrations; Elation Professionals® Los Angeles, Ca. - Wwww.elationlighting.com - Elation power spot 575 User Manual

Hide thumbs Also See for power spot 575:
Table of Contents

Advertisement

Power Spot 575™
3.9.6 Fixture Temperature
TEMP
This function allows you to read out the actual fixture operating temperature.
Press the Enter button to select this function or the Mode to button to cancel
and return to the main menu. Normal operating temperature should range
between 85˚C and 95˚C. Operating temperatures between 96˚C and 104˚C
are considered critical. Temperatures above 105°C will send the fixture into
protect mode and automatically switch the lamp off, the lamp will remain off
until internal temperature drops below 95˚C.
3.9.7 Fan Control
FANS
By using this function you can choose between 4 types of fan speed
operations. Use the Up and Down buttons to select the desired fan setting,
then press Enter to accept your setting or press the Mode button to cancel
and return to the menu. The chart below will detail the different fan settings:
HIGH
REG
LOOF
LOHI

3.9.8 Adjustments and Calibrations

ADJU
With this function you can adjust and calibrate the positions of the different
©Elation Professionals® Los Angeles, Ca.
The cooling fan works continuously at max. speed.
This is the default fan setting. In this setting an internal thermal
sensor constantly monitors the internal operating temperature and
regulates the fan speed to coincide with the internal temperature.
This function is designed for environments that require low
ambient noise. In this setting the fan will operate at the lowest
speed. When the maximum internal intolerable operating
temperature is reached the lamp will automatically shut off.
In this setting the fan will operate at the lowest speed. When the
maximum internal intolerable operating temperature is reached
the fan will automatically switch from low to high speed.
-
wwww.ElationLighting.com
23
-
Page

Hide quick links:

Advertisement

Table of Contents
loading