P IMPORTANT INFORMATION P KEEP FOR OPERATOR P IMPORTANT INFORMATION P OPERATOR MANUAL OM-HY-3E Part Number 121004 - Rev. B DOMESTIC MODELS: HY-3E,(2)HY-3E, (3)HY-3E HyPerSteam™ Atmospheric Convection Steamer Self-Contained Electric Heated Capacity: 3 Steamer Pans [per cavity] (12" x 20" x 2½”)
DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE OR THAT IS ALKALINE. WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
Door hinges are reversible (the door may be set to open from the left or right). Operating Controls are on the front panel. The HY-3E steamer holds three standard 12"x 20"x 2-½" deep pans [old model shown] Newer model HY-3E steamers (manufactured since...
Page 5
This typically requires it to have a minimum of 40 parts per million (ppm) total dissolved solids (TDS) as measured with a Groen Test Kit (P/N 110889). At high TDS concentrations, however, serious scaling problems may occur. Consult your local...
OM-HY-3E Installation and Start-Up WARNING THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.
E. Branch Circuit Protection line. A trap can cause pressure build-up in the cavity, which may cause the door gasket to leak. Each HY-3E Steamer should have its own DRAIN LINE INSTALLATION branch circuit protection. Current and power (OLDER MODELS WITH DRAIN BOX) demands for the different units are as follows: OPTION ONE: Use 1½”...
Page 8
Treated water (softened) is connected to the right valve fitting Rear view of (2) HY-3E — Note: The drain (facing the rear of the unit) and untreated water hoses, required for installation, are packed to the left valve fitting.
Page 9
OM-HY-3E Figure 2 - Drain and Water Connections for (2) HY-3E with optional twin hose connections. (Drain Kit P/N 125777) Figure 3 - Drain and Water Connections for (3) HY-3E with optional twin hose connections. (Drain Kit P/N 125777).
OM-HY-3E Operation WARNING ANY POTENTIAL USER OF THE EQUIPMENT SHOULD BE TRAINED IN SAFE AND CORRECT OPERATING PROCEDURES. seconds. When both probes fail, the light A. Controls will flash continuously and the beeper will Operator controls are on the front right of the unit.
Page 11
OM-HY-3E steam generator is at standby temperature 3. Open the door and slide the pans onto the and the cavity is hot enough to begin supports. If you will only be steaming one pan, steaming. put it in the middle position.
OM-HY-3E Cleaning To keep your HY-3E Steamer in proper working condition, use the following procedure to clean the unit. This regular cleaning will reduce the effort required to clean the steam generator and cavity. A. Suggested Tools WARNING DISCONNECT THE POWER SUPPLY 1.
Page 13
If the CLEAN light comes on again, call the authorized Groen Service agent in your area. (See listing enclosed The process for de-liming your HY-3E Steamer is with this manual). “simple, tool-less and quick. Adding de-limer/de-...
Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an...
OM-HY-3E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. REAR VIEW Description Description Right Side Panel 123134 096796 Cover, Fuse Box 119846...
Page 16
OM-HY-3E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. Description Description Heater Element, 200 V 123104 094118 Transformer 208/240/480V 106234 100912 Heater Element, 208 V...
Page 17
OM-HY-3E Parts List To order parts, contact your authorized Groen Service Agency. Supply the model designation, part description, part number, quantity, and when applicable, voltage and phase. Older Models New Model Description Description Red Timer Lamp 096898 Water Inlet Hose*...
OM-HY-3E Service Log Model No. Purchased From Serial No. Location Date Purchased Date Installed Purchase Order No. For Service Call Date Maintenance Performed Performed by...
Groen Foodservice Equipment (“Groen Equipment”) has been skillfully manufactured, carefully inspected, and packaged to meet rigid standards of excellence. Groen warrants its Equipment to be free from defects in material and workmanship for (12) twelve months with the following conditions an subject to the following limitations.
Page 24