Capacity: 3 Steamer Pans (12" x 20" x 2½”) KEEP THIS SUPPLEMENT WITH THE HY-3E OPERATOR AND SERVICE MANUALS. OPERATORS AND TECHNICIANS SHOULD READ, UNDERSTAND AND FOLLOW WARNINGS AND INSTRUCTIONS IN THIS SUPPLEMENT, THE SERVICE MANUAL AND THE OPERATOR MANUAL...
OM-HY-3E(CE) IMPORTANT — READ FIRST — IMPORTANT THESE APPLIANCES MUST BE INSTALLED BY A COMPETENT PERSON IN CONFORMITY WITH THE INSTALLATION AND SERVICING INSTRUCTIONS AND NATIONAL REGULATIONS IN FORCE AT THE TIME. PARTICULAR ATTENTION MUST BE PAID TO THE FOLLOWING: I.
Page 3
DO NOT USE ANY DE-GREASER THAT CONTAINS POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE OR THAT IS ALKALINE. WARNING: USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL WARRANTIES.
OM-HY-3E(CE) Installation Power Supply The HY-3E HyPerSteam™ CE model convection steamer operates at 400 Volts (Three Phase) or 230 Volts (One Phase). ELECTRICAL SUPPLY CONNECTION REQUIREMENTS Unit Maximum KW Field Wiring Current Demands 400 Volt - 3 Phase 14 AWG...
Drain Kit The CE Drain Kit includes a 21½" hose, but is otherwise identical to the standard HY-3E drain kit. It is recommended that there be at least a one inch free air gap between the end of the unit drain and the building drain.
OM-HY-3E(CE) Operation NOTE: All procedures are identical to those described the standard OM-HY-3E manual except as described herein. Operation The CE units contain a “Reset” Indicator Light on the Control Panel. This light comes on when the thermostat exceeds normal operating temperatures. The unit can not be operated until the “Reset” Switch is pressed.
Page 8
OM-HY-3E(CE) Wiring Harnesses Control Harness (Part No. 122096) Power Harness (Part No. 122095) Other Contactor (Part No. 122008) Thermostat and Reset Switch (Part No. 122009)
OM-HY-3E(CE) Parts List The following parts are unique to the CE Model HY-3E steamer. Part No. Description Qty. Part No. Description Qty. 121016 OM-HY-3E(CE) Supplement CE 116382 Reset Light 122001 Installation Label 122047 Back Panel 122005 Nameplate 122032 Overlay incorporating reset...
Page 11
Groen Foodservice Equipment ("Groen Equipment") has been skillfully manufactured, carefully inspected and packaged to meet rigid standards of excellence. Groen warrant their Equipment to be free from defects in material and workmanship for (12) twelve months, with the following conditions and subject to the following limitations.
Page 12
1055 Mendell Davis Drive OM-HY-3E(CE) Jackson, MS 39272 Part Number 121016 Telephone 601 372-3903 INTERNATIONAL Fax 601 373-9587 Revised 07/98...