Groen HY-PLUS-DS Operator's Manual

Atmospheric convection steamer on a cabinet base

Advertisement

Quick Links

OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
MODEL HY-PLUS-DS
ATMOSPHERIC
CONVECTION STEAMER
ON A CABINET BASE
· For Models: HY-6SM and HY-10SM
· Capacity: 6 or 10 Steamer Pans (12" x 20" x 2-1/2")
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
WARNING / FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, injury or
death. Read the installation, operating and maintenance
instructions thoroughly before installing or servicing this
equipment.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
PART NUMBER 159499 REV A (04/12)
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net

Advertisement

Table of Contents
loading

Summary of Contents for Groen HY-PLUS-DS

  • Page 1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: MODEL HY-PLUS-DS ATMOSPHERIC CONVECTION STEAMER ON A CABINET BASE · For Models: HY-6SM and HY-10SM · Capacity: 6 or 10 Steamer Pans (12” x 20” x 2-1/2”) THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
  • Page 2: Important Operator Warnings

    DO NOT USE CLEANING OR DE -LIMING AGENTS THAT CONTAIN SULFAMIC ACID OR ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT OF ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER. DO NOT USE CLEANING OR DE-LIMING AGENTS THAT CONTAIN MORE THAN 30% PHOSPHORIC ACID. OM-HY-PLUS-DS...
  • Page 3 THE OPERATOR AND DAMAGE THE EQUIPMENT. SERvICE PERFORMED BY OTHER THAN FACTORY AUTHORIZED PERSONNEL WILL vOID ALL WARRANTIES. DANGER: HIGH vOLTAGE EXISTS IN CONTROL COMPARTMENTS. DISCONNECT FROM BRANCH CIRCUIT BEFORE SERvICING. FAILURE TO DO SO CAN RESULT IN SERIOUS INJURY OR DEATH. OM-HY-PLUS-DS 3...
  • Page 4: Table Of Contents

    370 Wabasha St. Paul, Minnesota 55102 800 328-3663 or 612 293-2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy, Massachusetts 02269 NFPA/70 The National Electrical Code NSF INTERNATIONAL 789 North Dixboro Road P.O. Box 130140 Ann Arbor, Michigan 48113-0140 OM-HY-PLUS-DS...
  • Page 5: Equipment Description

    Equipment Description WARNING The Groen HY-PLUS Steamer is designed to bring you years of service. It has THE UNIT MUST BE INSTALLED BY two stainless steel cavities (cooking chambers) and a control compartment, which PERSONNEL WHO ARE QUALIFIED TO houses the electrical components and steam valves. In each cavity, a powerful blower WORK WITH ELECTRICITY AND PLUMBING.
  • Page 6: Installation

    MAKING ELECTRICAL OR MECHANICAL CHANGES TO THE UNIT WITHOUT APPROVAL The electrical schematic is located in the electrical enclosure and in this FROM THE GROEN FOOD SERVICE manual. In Canada provide electrical service in accordance with the Canadian ENGINEERING DEPARTMENT MAY VOID Electrical Code, CSA C22.1, Part 1 and/or local codes.
  • Page 7 Cold water (for faucet on 36” or wider units with kettles. Cold water (for condenser spray). Not used. Drain (for steamers and condenser spray). Also for kettle condensate and sink where used. Electrical (conduit through underside, terminals at the right on the inside). OM-HY-PLUS-DS 7...
  • Page 8: Initial Start-Up

    Turn off power to the gas or electric pressure boiler. Refer to the steam boiler operator manual, if necessary. If the unit functions as described above, it is ready for use. If it does not, contact your Authorized Service Agent. OM-HY-PLUS-DS...
  • Page 9: Operation

    A green light will come on. Steam will be delivered to the cavity until the timer is returned to OFF. Open the door. Using a pad or oven mitt to protect your hands, remove the pans from the steamer. To shut down the unit, turn the Timer to the OFF position. OM-HY-PLUS-DS 9...
  • Page 10: Cleaning

    BRUSH) THAT MIGHT SCRATCH STAINLESS STEEL SURFACES. SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW. DO NOT USE STEEL WOOL, WHICH MAY LEAVE PARTICLES IMBEDDED IN THE SURFACE, WHICH COULD EVENTUALLY CAUSE CORROSION AND PITTING. OM-HY-PLUS-DS...
  • Page 11: Maintenance

    If leakage is still present, repeat steps a. through c. until leakage stops. A Maintenance and Service Log is provided at the back of this manual. Each time maintenance is performed on the unit, enter the date the work was done, what was done, and who did it. OM-HY-PLUS-DS 11...
  • Page 12: Troubleshooting

    Is the door latch in need of adjustment? (See the Maintenance section). d. Is the unit level? Excessive steam coming from the vent a. Is the water supply turned on? pipe. b. Is the condenser hose kinked or obstructed? c. Is the condenser spray solenoid working? OM-HY-PLUS-DS...
  • Page 13: Parts List

    Parts List Steamer Cavity Only OM-HY-PLUS-DS 13...
  • Page 14 Tube, Supply 100552 Post, PC Board Mtg 099901 Lower Cavity Drain Hose 088848 Screw, 6-32 069777 Jumper, Voltage Select - SM & SG 100959 Harness, Spray Vavle - SM 137834 Cable Clamp 087958 Nut, 10-32 071256 Nut, 8-32 002632 OM-HY-PLUS-DS...
  • Page 15 Parts List Motor/Fan Assembly Description Part # Motor 096739 Slinger Washer 096831 Motor Mounting Plate 094134 Shaft Seal 096868 Plate Seal Holder 096752 OM-HY-PLUS-DS 15...
  • Page 16 Cover Assembly, Top 123182 Screw, 10-32 x 3/8 Truss 004173 Head Retainer, Top 123156 Screw, 8-32 x 3/8 slotted 004173 hex head Door Handle 129723 Door Hinge 094143 Door Hinge (10-Pan) 125928 Outer Door (6-Pan) 130858 Outer Door (10-Pan) 125922 OM-HY-PLUS-DS...
  • Page 17 Door Hinge (6-Pan) 130868 Door Hinge (10-Pan) 125928 Outer Door (6-Pan) 130858 Outer Door (10-Pan) 125922 Insulate Board (6-Pan) 094142 Insulate Board (10-Pan) 125926 Blower Cover/Right Pan 096788 Rack (6-Pan) Blower Cover/Right Pan 125902 Rack (10-Pan) X= not shown OM-HY-PLUS-DS 17...
  • Page 18 Drain Box with Spray Condenser Description Part # Solenoid Valve 099221 (Spray Condenser) Hose d “ ID x 8” Long 099282b Rubber Flap 099213 Spacer 099212 Hose, Outlet 1 “ID x 3” Long 099280b Anchor Coupling, d” NPT N89267 OM-HY-PLUS-DS...
  • Page 19 005056 8-32 x 1 1/4” Long Weld Assembly, Electronic 137256 Cabinet Bottom Screw, Hex HD, 069773 10-32 x 3/8” Long Plate, Hole Cover 137749 Hole Plug, 7/8” Dia. 137553 Harness, Power Cord, 137842 HY-6SM Nut, Hex Keps, #8-32 069784 OM-HY-PLUS-DS 19...
  • Page 20: Electrical Schematics

    Electrical Schematic Steamer Cavities OM-HY-PLUS-DS...
  • Page 21: Service Log

    Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Maintenance Performed Performed By OM-HY-PLUS-DS 21...
  • Page 22 OM-HY-PLUS-DS...
  • Page 23 OM-HY-PLUS-DS 23...
  • Page 24 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 unifiedbrands.net PART NUMBER 159499 REV A (04/12) © 2012 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.

Table of Contents