I/O Connector Connections - Omron F160 Vision Sensor Setup Manual

Hide thumbs Also See for F160 Vision Sensor:
Table of Contents

Advertisement

Connecting through the Parallel Interface
Wiring the Connector
4-1-2

I/O Connector Connections

1.
Use a flat-blade precision screwdriver to loosen the connector's set screw.
Counter-clockwise
2.
Insert the signal wire.
3.
Tighten the set screw to secure the wire. Tighten to a torque of 0.22 to
0.25 N•m.
Clockwise
4.
Insert the connector into the F160.
5.
Tighten the connector's mounting screws. Tighten to a torque of 0.22 to
0.25 N•m.
Use an F160-VP Parallel I/O Cable (sold separately) to connect to the F160's
I/O connector. Align the connectors and insert the cable's connector straight
Section 4-1
31