Installation Precautions
Ambient Temperature
1,2,3...
Noise Resistance
1,2,3...
1-1-2

Component Installation and Handling

OMRON Components
Connecting Cables
Handling the Camera
1,2,3...
1.
Maintain a minimum clearance of 50 mm above and below the F160 to im-
prove air circulation.
2.
Do not install the F160 immediately above significant heat sources, such
as heaters, transformers, or large-capacity resistors.
3.
Do not let the ambient operating temperature exceed 50°C (122°F).
4.
Provide a forced-air fan cooling or air conditioning if the ambient tempera-
ture is near 50°C (122°F) so that the ambient temperature never exceeds
50°C (122°F).
Control panel
F160
Louver
Use the following measures to help increase noise resistance.
1.
Do not install the F160 in a cabinet containing high-voltage equipment.
2.
Do not install the F160 within 200 mm of power cables.
Power cable
200 mm min.
200 mm min.
F160
Use a Camera, Camera Cable, and Console designed specifically for the
F160.
Always turn OFF the F160's power before connecting or disconnecting a cam-
era or cable.
The Camera's case is connected to the 0V line in the internal circuits. Observe
the following precautions to prevent noise interference.
1.
Do not ground the Camera.
2.
Do not remove the base attached to the Camera.
3.
Do not remove the core attached to the F150-VS Camera Cable.