Glass Replacement; Blower Installation - Quadra-Fire Direct Vent Room Heater GARNET-D-CSB Owner's Manual

Garnet-t direct vent room heater
Table of Contents

Advertisement

G. Glass Replacement
Turn the appliance OFF and let it cool down before replacing
the glass.
Lift off the appliance top and place it on a flat surface, with
the porcelain side up, to prevent damage.
Remove the appliance front by sliding it upward in the
grooves, being careful not to chip the porcelain. Lay the
front face up on a flat surface.
Unhook latch now exposed on top of the appliance. Pull the
top of the glass frame towards you and lift it out of the retainer
along the bottom of the firebox.
Replacement is the reverse of the removal.
CAUTION
Handle glass assembly with care.
• Inspect the gasket to ensure it is undamaged.
• Inspect the glass for cracks, chips or
scratches.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass door
removed, cracked, broken or scratched.
• Replace glass assembly as a complete
assembly.
H. Blower Installation
TOOLS REQUIRED: Short #2 Philips head screwdriver;
11/16" wrench; and a 3/8" wrench.
FROM THE KIT YOU WILL NEED: Blower in mounting
with wiring harness; speed control (rheostat); speed
control knob; pal nut; snap disc; screws; and 1 zip-tie.
FROM THE APPLIANCE COMPONENT BAG YOU
WILL NEED: Snap disc bracket; 10-32 nut.
KIT CONTENTS:
1 - Blower Mounted in Housing
2 - Speed Control Knob
3 - Pal Nut
4 - Ceramic Snap Disc
5 - Speed Control (Rheostat)
6 - Wire Harness (attached to Blower)
7 - 12 Screws
8 - 12 inch Glass Tape
9 - 1 Zip Tie
10 - Bracket #1
11 - Snap Disc Bracket
September 1, 2008
Figure 8.10
contents of the kit are listed at left. If any of the parts are
missing or damaged, please contact your dealer for replace-
ments.
NOTE: Not all parts will be used for this installation.
Figure 8.11
Remove the back shield by removing the two screws along
the top of the shield.
Place the blower on the floor behind the appliance and route
the ends of the wiring harness through the rubber grommet
on the underside. Holding the blower in place, attach it to the
appliance with four of the screws provided.
Quadra-Fire · Garnet-T · 7016-127F
10
Open and inspect contents of the blower kit. The
Remove the top of the appliance and set aside.
11
Page 33